LK Floor Heating | Assembly Instructions | LK Room Temperature Control ICS-RF8
7
EN.33.C.104.1012
to prevent the pump from seizing during long downtime (e.g. during the summer). NOTE: wiring/connection
to the relay may only be performed by a qualified electrician.
See diagram below.
See also
BUS
section.
WARNING! RISK OF ELECTRIC SHOCK!
Disconnect all incoming power to the device before the high
voltage lid is opened.
Circuit diagram for connecting the pump
Relay for heat source (illus. 10)
Boilers/heat sources can be controlled via the heat source relay. The relay is located under the lid of "high
voltage side" of the receiver unit.
NOTE: the relay contact is "potential free" (volt free), which means that the boiler relay contacts must be
powered from an external source and NOT from the receiver unit. The boiler/heat source will fire approximately
6 minutes after any one channel calls for heat. When the relay is activated, the Boiler LED is lit.
NOTE: wiring/connection to the relay may only be performed by a qualified electrician. See diagram below.
See also
BUS
section.