LK Floor Heating | Assembly Instructions | LK Room Temperature Control ICS-RF8
12
EN.33.C.104.1012
1. Heat on/off and minimum and maximum limit
2. Number of the receiver unit and error code
3. Room temperature measurements enabled
4. OK symbol
5. Indicates constantly disconnected weekly program
6. Temperature indicator
7. Setup menu
8. Holiday function
9. OFF/ON selection
10. Local/general set-up
11. Control channel/day
12. Operation
13. Key lock symbol
14. Communication symbol
15. Battery indicator
Description of the thermostat menus/settings
LK ICS-RF can be adjusted and set up as following:
Checking signal strength
Before the system is put into operation for the first time the signal strength should be checked so that all
thermostats are located within "broadcasting" area.
Check signal strength as follows:
1.
Press
Mode
until
flashes, confirm using
Mode.
2. Press the right arrow until
RFST
(radio signal strenght) appears in the display, confirm using
Mode.
Allow the unit stabilise for approximately five minutes.
3. Read the value. The device will automatically return to normal view after 30 minutes.
4. Repeat steps 1-3 for other thermostats in the system.
Signal strength can be checked for all units simultaneously to save time.
Signal strength
Comments
0-20
Too low to ensure their
functioning. Take action.
21-100
Excellent.
If necessary, the signal can be improved by placing the thermostat closer to the receiver unit, if possible.
Alternatively, the radio link can be moved by using the LK Antenna Cable. If the problem persists, the signal
is strengthened by use of LK Repeater.