MAINTENANCE
Cleaning Impeller and Volute
Periodic cleaning of the pump parts will prolong the life and
efficiency of the pump.
1. Remove the 5 bolts and 5 washers (1, 2) that secure the base (4)
to the volute (3), then separate the base (4) from the volute (3).
2.
s
!
WARNING
Do not remove the motor
housing cover. Warranty is void if the motor housing cover,
impeller or seals have been removed.
3. Remove all debris (gravel, sand, floating debris, etc.)
from the sump basin.
4. Clean the impeller (5) and the volute passage (6).
Do not use strong solvents.
a.
s
!
CAUTION
Do not remove the impeller.
Removal of the impeller requires special tools and is to be
done only by an authorized service center.
5. Be sure the impeller turns freely after cleaning.
6. Place the rubber gasket (7) over the base (4).
7. Attach the base (4) to the volute (3) and secure it with
the 5 bolts and 5 washers (1, 2).
REPLACEMENT PARTS
Part No.
Description
Item No.
110970301
Float Assembly
8
A-N661
1
2
4
3
5
8
6
7