PUMP PERFORMANCE AND SIZING CHART

MODEL 

NO.

CATALOG 

NO.

HP

PH

VOLTS

HZ

AMPS

GPM @ HEAD

SHUT OFF 

(FT)

POWER 

CORD (FT)

10'

20'

40'

60'

80'

100'

120'

IGP-M231/ 

IGP-M201

515865/

515855

2

1

230/

208

60

13.9

33

32

31

30

25

20

10

130

15'

GB

INTRODUCTION

Little Giant Submersible IGP-M231/IGP-M201 Series Grinder Pumps are 
recommended for use in basins or lift stations and suitable for pumping 
residential sewage, effluent, wastewater and other non-explosive, non-
corrosive liquids.
Little Giant Grinder pumps utilize a cutting mechanism located on the 
suction side of the pump. The solids are cut into a slurry which pass 
directly through the volute into the discharge line by an impeller.
Little Giant offers complete control panel systems for automatic operation 
along with a complete line of alarms, basins, covers, and check valves. A 
Little Giant Pump panel or capacitor and relay kit must be used for proper 
operation.
Little Giant pumps are carefully packaged, 100% inspected and tested to 
insure safe operation and delivery. When you receive your pump, examine 
it carefully to determine that there are no broken or damaged parts which 
may have occurred during shipment. If damage has occurred, make 
notation and notify the firm from which you purchased the pump. They will 
assist you in replacement or repair, if required. Pump must be installed by 
experienced professionals only, and in accordance with local plumbing 
and electrical codes.

SPECIFICATIONS

Discharge Size: IGP-M231/IGP-M201 - 1-1/4" FNPT Vertical
Operating
Capabilities:
 

140 °F (60 °C)

Pump Housing:  Cast iron with epoxy paint coating 
Volute: 

Cast iron with epoxy paint coating

Impeller: 

Brass with pressure relief vanes

Motor: 

3450 RPM with automatic high temperature protection

Hardware: 

300 series stainless steel 

Bearings: 

Upper and lower ball

Shaft Seal: 

Type 21 mechanical, spring loaded, rotating carbon 
with Fluoroelastomer (FKM) bellows and ceramic 
stationary with Fluoroelastomer (FKM) O-ring

Power Cord: 

14 AWG 4-conductor, copper, stranded

Cooling: 

The motor housing contains a dielectric oil to provide 
cooling for the motor and to lubricate the bearings and 
seals. These pumps are capable of operating with the 
motor housing partially exposed for extended periods of 
time, providing sufficient motor cooling and bearing 
lubrication. However, for the best cooling and the 
longest motor life, the liquid level being pumped should 
normally be above the top of the cast iron motor cover.

Cutters: 

440C stainless steel, hardened to Rockwell C 55-60

SAFETY GUIDELINES

Read all instructions and Safety Guidelines thoroughly. Failure to follow 
the guidelines and instruction could result in serious bodily injury and/or 
property damage.

WARNING: Risk of electric shock. This pump is supplied with a 
grounding conductor. To reduce the risk of electric shock, be certain that 
it is connected only to a properly grounded, grounding-type receptacle in 
the control panel.
When a pump is in a basin, etc., do not touch motor housing, pipes or 
water until unit is unplugged or shut off. If your Installation has water or 
moisture present, do not touch wet area until all power has been turned 
off. If shut-off box is not accessible, call the electric company to shut off 
service to the house, or call the local fire department for instructions. 
Failure to follow this warning can result in fatal electric shock. 
The flexible jacketed cord assembly mounted to the pump must not be 
modified in any way. Do not use the power cord for lifting the pump.

 

1.  DO NOT USE TO PUMP FLAMMABLE OR EXPLOSIVE FLUIDS 

SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC. FAILURE TO 
FOLLOW THIS WARNING CAN RESULT IN PERSONAL INJURY 
AND OR PROPERTY DAMAGE.

 2.  The pump motor is equipped with an internal thermal protector switch 

that opens to stop the motor when exceeding normal operating 
temperatures. This switch will reset itself and start the pump when cooled 
to normal temperatures.

 3.  During normal operation the grinder pump is immersed in water. Also, 

during rain storms, water may be present in the surrounding area 
of the pump. Caution must be used to prevent bodily injury when 
working near the pump.

  a.  Electrical power must be disconnected prior to touching, servicing 

or repairing the pump.

  b.  To minimize possible fatal electrical shock hazard, extreme care 

should be used when changing fuses. Do not stand in water 
while changing fuses or insert anything other than a fuse in the 
fuse socket.

 4.  Do not run the pump in a dry basin. If the pump is run in a dry basin, 

the surface temperature of the pump will rise to a high level. This high 
level could cause skin burns if the pump is touched and will cause 
serious damage to your pump.

 5.  Do not oil the motor. The pump housing is sealed. A high grade 

dielectric oil devoid of water has been put into the motor housing at 
the factory. Use of other oil could cause serious electric shock and/or 
permanent damage to the pump.

 6.  Do not install in locations classified as hazardous in accordance with 

the National Electric Code, ANSI/NFPA 70.

 7.  Do not place hands, feet or clothing near the cutter mechanism when 

there is any possibility the pump is connected to a power source. This 
pump contains a cutting mechanism with very sharp edges that can 
cause severe bodily injury.

INSTALLATION

For automatic operation, pump must be wired into a control panel. 
Installation instructions are included with all Little Giant control panels and 
should be referred to for installation. 
Pump will not run if wired directly into an electrical outlet. This pump 
requires a Little Giant capacitor kit and or control panel, which contains the 
appropriate start and run capacitors in conjunction with a relay for proper 
operation. Refer to the instruction manual for capacitor kit or control panel 
to obtain proper component values. If this pump is run with incorrect 
capacitors or relay, there could be severe damage to the pump motor and 
or control panel. 
Pump must be installed in a suitable basin, which is at least 24" in diameter 
and 36" deep, and vented in accordance with local plumbing codes. 
It is recommended for best performance and satisfactory installation to 
use a complete factory built basin package system. This system includes 
optimum materials of construction for operation. 

IGP-M231

IGP-M201

1 Phase

Franklin Electric 

Oklahoma City, OK 73127

Phone: 866.281.2859

Fax: 866.271.2709

[email protected]

1

Summary of Contents for 515855

Page 1: ...until all power has been turned off If shut off box is not accessible call the electric company to shut off service to the house or call the local fire department for instructions Failure to follow t...

Page 2: ...al plate and volute To gain access to the rotating cutter remove the volute by removing the three flange hex head cap screws Remove volute by carefully tapping and prying the volute off the seal plate...

Page 3: ...achet la pompe Ils vous aideront pour le remplacement ou la r paration si n cessaire La pompe doit uniquement tre install e par des professionnels exp riment s et respecter les r glements locaux de pl...

Page 4: ...cules solides Une valve de porte devrait suivre la valve de contr le ch que pour permettre le nettoyage p riodique de la valve de contr le ch que ou le d placement de la pompe Le reste de la d charge...

Page 5: ...able de energ a Calibre 14 con 4 conductores cobre trenzado Enfriamiento El estator contiene un aceite diel ctrico para enfriar el motor y lubricar los cojinetes y obturadores Estas bombas pueden func...

Page 6: ...activar el cortacircuitos antes de trabajar en la bomba Limpieza del ensamblado del cortador espiral e impulsor PRECAUCI N Al trabajar en la bomba siempre desconecte el cable de alimentaci n adem s de...

Page 7: ...20476 Retaining Plate Cutter 1 5 14940256 Screw Washer Hex Head 3 8 16 x 1 1 2 SST 3 6 903740 Screw Washer Hex Head 5 16 18 x 1 2 SST 3 950532 Start Capacitor 1 950533 Run Capacitor 1 950537 Start Rel...

Page 8: ...drilled in discharge pipe approximately 2 above discharge connection If there is already a hole drilled check for stuck debris Couper le courant pendant 1 minute environ puis recommencer R p ter cett...

Page 9: ...rucciones o defectos Basin too small for inflow Bassin de r ception trop petit pour l afflux El fondo del sumidero es muy peque o o est inundado Install larger basin Installer un bassin plus grand Ins...

Page 10: ...erate dry fluid supply cut off 13 Products in which the sealed motor housing has been opened or the product has been otherwise dismantled by customer 14 Products in which the cord has been cut to a le...

Page 11: ...des changements la conception et ou des am liorations ses produits sans pour autant imposer une quelconque obligation sur elle m me d apporter des modifications ou des am liorations correspondantes d...

Page 12: ...erior los 140 F 60 C 12 Productos en los cuales la bomba fue habilitada para operar en seco sin suministros de fluidos 13 Productos en los cuales la carcasa sellada del motor fue abierta o el producto...

Reviews: