5-Series Submersible Pumps

OWNER'S MANUAL

English

EN

This submersible multi-purpose is designed for clear water transfer applications and household water 
removal. The pump is for use with water only.
Do NOT use this pump for:

• Flammable, combustible, or explosive fluids
• Transferring potable water
• Effluent or sewage applications
• Applications where debris (gravel, sand, etc.), abrasives, or 

corrosives are present

• For pumping seawater
• Sprinkler applications, as this pump does not deliver enough 

pressure

• Locations classified as hazardous according to the National Electric Code (ANSI/NFPA)

This pump series is available in manual and automatic models. The manual pump can be converted to 
operate in automatic mode by installing a separate liquid level control.
The pump motor is equipped with an automatic resetting thermal protector and may restart unexpectedly. 
Thermal Protector tripping is an indication of motor overloading or overheating. This can be caused by 
application issues such as an obstructed pump impeller, pump running dry, pump air-locked, pump short 
cycling, excessively high or low voltage supply, or possibly a pump, motor, bearing, or seal that has 
reached the end of its useful life.
Please examine your pump carefully to ensure that no damage occurred during shipment. If damage has 
occurred, please contact the place of purchase. They will assist you in replacement or repair, if required.
This product is covered by a Limited Warranty for a period of 12 months from the date of original purchase 
by the consumer. For complete warranty information, refer to 

www.LittleGiant.com

.

Specifications

Flow Rates

Voltage

HP

PSI

Hz

Watts

Amps (FLA)

Breaker Amps

115

1/6

11.4

60

220

2.0

15 A

230

1/6

11.4

60

220

1.0

10 A

Gallons/Liters per Hour

At Height: 

(Head)

1 ft (0.3 m)

3 ft (0.9 m) 5 ft (1.5 m)

10 ft (3 m)

20 ft (6 m)

Shut Off

115 VAC

1500 / 5678

1464 / 5542

1395 / 5281

1191 / 4508

528 / 1999

26.3 ft (8 m)

230 VAC

1500 / 5678

1464 / 5542

1395 / 5281

1191 / 4508

528 / 1999

26.3 ft (8 m)

Summary of Contents for 305624001

Page 1: ...ping is an indication of motor overloading or overheating This can be caused by application issues such as an obstructed pump impeller pump running dry pump air locked pump short cycling excessively h...

Page 2: ...sing severe injury or death by electrical shock are present in this unit To reduce risk of electrical shock disconnect power before working on or around the system More than one disconnect switch may...

Page 3: ...r leaking pump due to power outages discharge line blockage or any other reason an automatic back up system and or an alarm should be installed Do not run the pump dry If run dry the surface temperatu...

Page 4: ...models are supplied with a stripped wire cord end Power connections must be made within a junction box and must comply with the National Electrical Code Wires are color coded as follows Green yellow...

Page 5: ...he atmosphere through a breather tube routed through the pump s power cord Non restric tive air flow in the breather tube is required 1 Place the pump in an empty test basin 2 Connect the pump to powe...

Page 6: ...e of the power cord or stripped end of the power cord 3 Release the bulb to induce suction vacuum 4 Listen for the switch to make a click sound 5 Once the suction vacuum equalizes listen for the diaph...

Page 7: ...ute to the motor housing with screws 10 Replace the screen onto the volute Risk of severe injury or death by electrical shock high temperatures or pressurized fluids Always unplug the pump power cord...

Page 8: ...rcuit breaker or replace fuse Defective motor Replace pump Pump will not shut off Liquid inflow matches pump capacity Larger pump required Pump runs but does not dis charge liquid Lift too high for pu...

Page 9: ...a activaci n del protector t rmico es una indicaci n de sobrecarga o sobrecalenta miento del motor Esto puede deberse a problemas de aplicaci n como un impulsor de la bomba obs truido una bomba que fu...

Page 10: ...ctrica desconecte la energ a antes de trabajar en el sistema o cerca de l Es posible que sea necesario m s de un interruptor de desconexi n para cortar la energ a del equipo antes de realizarle un man...

Page 11: ...cionar vac a la bomba Si la hace funcionar vac a la temperatura de la superficie de la bomba aumentar al punto que podr a provocar quemaduras si se la toca y le causar serios da os a su bomba No apliq...

Page 12: ...ades de 230 V se recomienda un fusible de 5 0 amperios Modelos con cables con extremos pelados Algunos modelos vienen con un extremo del cable pelado Las conexiones de alimentaci n deben reali zarse d...

Page 13: ...able de alimentaci n de la bomba Es obligatorio que el aire fluya sin restricciones por el tubo de respiraci n 1 Coloque la bomba en un recipiente de prueba vac o 2 Conecte la bomba a una fuente de al...

Page 14: ...del cable de alimentaci n 3 Libere la pera para provocar la succi n el vac o 4 Escuche que el interruptor haga un clic 5 Cuando la succi n el vac o se iguale escuche para verificar que el interruptor...

Page 15: ...motor con tornillos 10 Reemplace la pantalla en la voluta Riesgo de lesiones graves o muerte por descarga el ctrica temperaturas elevadas o l quidos presurizados Siempre desenchufe el cable el ctrico...

Page 16: ...e apaga El flujo de entrada de l quido coincide con la capacidad de la bomba Se requiere una bomba m s grande La bomba fun ciona pero no descarga l quido Elevaci n demasiado alta para la bomba Revise...

Page 17: ...e et peut red marrer inopin ment Le d clenchement du disjoncteur thermique indique la surcharge ou la surchauffe du moteur Ce d clenchementpeut tre caus par des probl mes d application notammentl obst...

Page 18: ...ev es susceptibles d entra ner par choc lectrique des blessures graves ou la mort Pour r duire le risque de choc lectrique d branchez l alimentation avant de travailler sur le syst me ou autour de cel...

Page 19: ...pas faire fonctionner la pompe sec En cas de fonctionnement sec la temp rature la surface de la pompe augmentera un niveau susceptible de causer des br lures cutan es en cas de contact et entra nera...

Page 20: ...de fils aux extr mit s d nud es Certains mod les sont fournis avec des fils aux extr mit s d nud es Les connexions d alimentation doivent tre r alis es install s dans une bo te de jonction en conform...

Page 21: ...t dans le cordon d alimentation de la pompe Une a ration non restrictive est n cessaire dans le tube reniflard 1 Placer la pompe dans un bassin d essai vide 2 Raccordez la pompe une alimentation avec...

Page 22: ...d nud e du cordon d alimentation 3 Rel chez la poire pour provoquer l aspiration le vide 4 Attendez que l interrupteur mette un clic 5 Une fois l galisation r alis e gr ce l aspiration au vide attend...

Page 23: ...z l cran sur la volute Risque de blessure grave ou de mort par lectrocution temp rature lev e ou liquide sous pression Avant d effectuer des travaux sur la pompe ou l interrupteur vous devez toujours...

Page 24: ...iquide est adapt aux capac it s de la pompe Une pompe de plus grande taille est n cessaire La pompe fonc tionne mais elle ne refoule pas le liquide La pompe est soulev e trop haut V rifiez le rendemen...