2016 | Lithionics Battery LLC | SOCV6 REV0
PRE-RELEASE
19
NOTE:
Below commands don’t have any values. These commands execute actions as described
below.
AT+CALIB – Zero point calibration (ensure no charge/discharge loads are present before executing)
AT+LIST – Lists all stored values.
AT+RESET – Resets IP parameters to factory defaults and creates a new MAC address where the
last 4 digits are random.
AT+END – End Setup mode and resume to normal Data mode.
AT+SETUP – Halt normal operation and enter Setup mode.
Data Mode commands:
During data mode SOC Gauge can receive and process real time commands
listed below. Commands must start with “$” and end with CR+LF termination.
$STREAMOFF – Turn off data stream.
$STREAMON – Turn on data stream.
$POLL – Poll data one time.
$BATOFF – Turn off battery power
$BATON – Turn on battery power.
$CHARGEON – If battery is over-discharged with open CL this command forces the contactor to
latch ON to allow charging to begin. BMS expects voltage rise to qualify that it is being charged.