Lithionics Battery LLC |2013
3.2 - Tightening Torque:
All main battery terminal connections must be tightened to a max torque value as indicated below.
Do not exceed this value
. Brass/copper conductors have a much lower shear strength than steel.
M6 Modular Terminals
60 inch pounds/7 N-m
5/16 Bolt SAE Style
Terminals
100 inch pounds/11 N-m
(Use a Crescent Wrench
to stabilize the base of
the Terminal)
3.3 - Push Button Operation:
Turn the Battery “On” After Installation!
On top of your battery is EITHER a low-profile stainless-steel pushbutton momentary switch OR a red
push button which operates the batteries output. It operates simply by pressing once OR by pressing
and holding the button.
To turn your battery ON: Press and hold the button for 1 second and release.
To turn your battery OFF: Press and hold the button for 4 seconds and release.
3.4 - Optional Wireless Remote Operation:
With the optional Wireless Remote you can turn the battery on/off while being up to 100 feet away.
To turn battery output ON
To turn battery output OFF
Press the UNLOCK symbol on the remote.
Press the LOCK symbol on the remote.