Lithionics Battery LLC |2013
3.
Place the battery in a cool, dry environment. Ideally 70-80F (21-26C).
Example: a battery installed into a JetSki, Classic Car or Boat planned for a 6 month
storage…filling the battery UP and turning it OFF will enable this storage period.
-
Upon completion of long term storage, press the button for 1 second and attempt an engine
start within 10 seconds. If the battery fails to start the engine to initiate alternator
recharging, simply attach a low-cost Lithionics charger for 30 to 60 minutes.
6. Troubleshooting
Symptom
Cause
Remedy
No voltage
A.
Battery output is off.
B.
Battery is not charged.
C.
Battery is overheated.
D.
Battery was short circuited.
A.
Turn battery on. See section
3.3.
B.
Charge battery. See section
4.
C.
Remove battery from heat
source or lessen load on
battery (max 80A
continuous). See section
2.3.
D.
In the event battery has
been short circuited it will
auto power off. Remove
battery from short circuit
load and turn battery on.
See section 3.3.
Not charging
A.
Battery is off.
B.
Wrong charger connected.
A.
Turn battery on. See
section 3.3.
B.
Verify the correct
charger is applied. See
section 4.
Poor performance
A.
Battery is not charged.
B.
Wrong application.
A.
Charge battery. See
section 4.
B.
See front page for
operating specifications.