background image

Lithionics Battery LLC |2013 

 

3.

 

Place the battery in a cool, dry environment. Ideally 70-80F (21-26C). 
Example:    a battery installed into a JetSki, Classic Car or Boat planned for a 6 month 
storage…filling the battery UP and turning it OFF will enable this storage period. 

-

 

Upon completion of long term storage, press the button for 1 second and attempt an engine 
start within 10 seconds.   If the battery fails to start the engine to initiate alternator 
recharging, simply attach a low-cost Lithionics charger for 30 to 60 minutes.

 

6. Troubleshooting

 

 

Symptom 

Cause 

Remedy 

No voltage 

A.

 

Battery output is off. 

B.

 

Battery is not charged. 

C.

 

Battery is overheated. 

D.

 

Battery was short circuited. 

A.

 

Turn battery on. See section 
3.3. 

B.

 

Charge battery. See section 
4. 

C.

 

Remove battery from heat 
source or lessen load on 
battery (max 80A 
continuous). See section 
2.3. 

D.

 

In the event battery has 
been short circuited it will 
auto power off. Remove 
battery from short circuit 
load and turn battery on. 
See section 3.3. 

Not charging 

A.

 

Battery is off. 

B.

 

Wrong charger connected. 

A.

 

Turn battery on. See 
section 3.3. 

B.

 

Verify the correct 
charger is applied. See 
section 4. 

Poor performance 

A.

 

Battery is not charged. 

B.

 

Wrong application. 

A.

 

Charge battery. See 
section 4. 

B.

 

See front page for 
operating specifications. 

 

Summary of Contents for NeverDIE

Page 1: ...X 40 40 Amps GT Series 2C or 2 Times Amp Hour Capacity Operating Conditions Do Not Operate Under The Hood Until You Confirm the Temperature and Air Flow Characteristics of Your Vehicle See Section 2 3 Operating Temperature Range 12V and GT12V Series 25F to 125F GT Series 15F to 125F Storage Temperature Range 4F to 95F Water Resistant REMOVE THE BATTERY FROM THE PACKAGING AND IMMEDIATELY USE A VOLT...

Page 2: ...cification 2 2 Waterproof Specification 2 3 Temperature Specification 3 NeverDIE Battery Operation 3 1 Connecting Your NeverDIE Battery 3 2 Terminal Tightening Torque 3 3 NeverDIE Pushbutton operation 3 4 Optional NeverDIE Wireless Remote Operation 4 Charging Your Battery 4 1 Supported Chargers 4 2 Connecting Your Battery 5 Storing Your Battery 6 Troubleshooting ...

Page 3: ... to these test standards in your application THIS TEST DOES NOT CERTIFY THAT YOUR BATTERIES WILL ENDURE IN THIS ENVIRONMENT IT IS A TEST OF SAFETY TO SIMULATE CRASH CONDITIONS OR SHIPPING DAMAGE 2 2 Water Moisture Specification All Lithionics Batteries are water resistant not waterproof This means the battery is protected against falling water when tilted up to 15 degrees in each direction from no...

Page 4: ...a black and a red cap The red indicates positive and black indicates the negative output Lithionics Battery caps are placed like below Near your battery terminals locate the red positive symbol like this This symbol will always be found beside or at the bottom of the positive terminal Many vehicles are designed to ensure proper air flow over the battery and have an insulated battery box to ensure ...

Page 5: ...nstallation On top of your battery is EITHER a low profile stainless steel pushbutton momentary switch OR a red push button which operates the batteries output It operates simply by pressing once OR by pressing and holding the button To turn your battery ON Press and hold the button for 1 second and release To turn your battery OFF Press and hold the button for 4 seconds and release 3 4 Optional W...

Page 6: ...per working order or a Lithionics Battery LiFePO4 Charger Failure to do so will void the battery s warranty Other chargers are factory approved but you must report that charger to the factory in an email request to your sales representative or info lithionicsbattery com and obtain formal approval 4 2 Connecting Your Battery to a Charger Step 1 Verify that the battery output is ON This can be done ...

Page 7: ...ans the Battery Will Enter Sleep Mode with a Power Reserve But Only for a Limited Time Before Recharging is Required 1 Fully charge your battery 2 Press the NeverDIE switch for 5 FULL SECONDS and confirm the battery is OFF DO NOT USE A SOLAR CHARGER OR SOLAR CHARGE CONTROLLER ON ANY LITHIONICS ENGINE STARTING BATTERIES THIS WILL VOID YOUR WARRANTY OUR ENGINE STARTING BATTERIES ARE DESIGNED TO ABSO...

Page 8: ...oting Symptom Cause Remedy No voltage A Battery output is off B Battery is not charged C Battery is overheated D Battery was short circuited A Turn battery on See section 3 3 B Charge battery See section 4 C Remove battery from heat source or lessen load on battery max 80A continuous See section 2 3 D In the event battery has been short circuited it will auto power off Remove battery from short ci...

Reviews: