User Manual 

EPX-410D/420D/430D

4/8 Channel Switch Pack Series

 

 

 

 

 

 

410D/420D/430D/810D/820D/830D [EUM-B]                                                                                       

430D/810D/820D/830D 

Switch Pack Series 

           

 

                                    1 

   

                                                           

Summary of Contents for 4 Channel Switch Pack Series

Page 1: ...EPX 410D 420D 430D 810D 820D 830D User Manual EPX 410D 420D 430D 4 8 Channel Switch Pack Series 410D 420D 430D 810D 820D 830D EUM B 430D 810D 820D 830D Switch Pack Series 1...

Page 2: ...ing on Level Setting 3 8 Software Version Check 4 EDX Systems 4 0 EDX Mode 4 1 ID Number Setting 3 2 Zone Number Setting 4 3 Scene Save and Recall 4 4 Primary Secondary Scene and Scene Overlap ON OFF...

Page 3: ...ions 1 AC Input AC 100 240V 2 Output EPX 410D 10A per channel 3 Protocol DMX 512 EDX 4 Dimensions EPX 410D 420D 430D 162 EPX 810D 820D 830D 234 5 Weight EPX 410D 420D 430D 0 60 EPX 810D 820D 830D 0 90...

Page 4: ...EPX 410D 420D 430D 810D 820D 830D 2 3 Dimensions 410D 420D 430D 810D 820D 830D EUM B 4...

Page 5: ...OFF 4 Power input 6 EDX DMX 512 8 EDX DMX 512 signal indicator 2 1 4 410D 420D 430D 810D 820D 830D EUM B 2 DMX to set DMX address FCN function selection exit without saving 5 4 channel outputs 7 EDX 1...

Page 6: ...EPX 410D 420D 430D 810D 820D 830D 2 5 Wiring Diagram One Channel 410D 420D 430D 810D 820D 830D EUM B One Channel 6...

Page 7: ...n press First channel is on ON mode Second channel is on OFF mode 410D 420D 430D 810D 820D 830D EUM B at the same time and restart the device initialize the device Address Setting Standard DMX console...

Page 8: ...an be adjusted from 0 to 100 410D 420D 430D 810D 820D 830D EUM B DMX IN setting after initialization turns d OF Press to confirm and back to time screen DMX signal ot receive DMX signal Delay Time Set...

Page 9: ...the switching on level from 10 to 90 DMX to save off level is 5 lower than switching on level For example if switching By default the channel mode refer 3 6 is switch mode In switch mode if you press...

Page 10: ...n DMX 512 mode or EDX mode EDX EPX devices can be controlled by DMX 512 controllers can be recalled its stored lighting scenes by connecting to ECP scene lease refer EDX wiring guide on Lite Puter s w...

Page 11: ...anel 2 controls EDX If there are both DMX 512 and EDX signal present DMX 410D 420D 430D 810D 820D 830D EUM B devices with ECP scene panels ECP scene panel 1 controls EDX EPX device 1 ECP scene panel 2...

Page 12: ...m 02 to 03 zone number start channel 410D 420D 430D 810D 820D 830D EUM B Setting device must have a ID number When one device s working alone but when several devices working together each devic press...

Page 13: ...ress or to select a channel Here we select channel one to set the level of channel 1 Here we press to select other channel Repeat step 2 and 3 to edit the scene LED shows It means that the current sce...

Page 14: ...scenes 420D is OFF 420D is ON When overlap SC5 to SC2 the first channel is ON Primary and Secondary Scene Function On usual press a scene button 1 6 on the control panel the corresponding scene will b...

Page 15: ...scenes are recalled by 106 of zone 1 only channel 1 2 on EPX 420D will change their dimming levels If scenes are 106 of zone 2 only channel 3 4 on EPX 420D will change their dimming levels Figure Cha...

Page 16: ...belongs to zone 1 STEP4 Repeat step 2 3 4 5 to set zone number 410D 420D 430D 810D 820D 830D EUM B Enable Disable Partition Function several times until LED shows It means partition function is disab...