31
LPP PetRoL GeNset oPeRAtoRs' hANdbook
seRVICe ANd stoRAGe
INfReqUeNt seRVICe
If the unit is used infrequently, difficult starting may result. To eliminate hard
starting, run the generator at least 30 minutes every month. Also, if the unit will
not be used for some time, it is a good idea to drain the fuel from the carburetor
and petrol tank.
LoNG teRm stoRAGe
When the generator set is not being operated or is being stored more than one
month, follow these instruction:
1.Replenish engine oil to upper level.
2.Drain petrol from fuel tank (1), fuel line, fuel cock, and carburetor float bowl.
3.Pour a cup of clean engine oil in the tank (2), shake the tank (3) and then drain
the excess oil (4).
4.Pour about one teaspoon of engine
oil through the spark plug hole,
pull the recoil starter several times
and replace the plug. Then pull the
starter until you feel the piston is on
its compression stroke and leave
it in that position. This closes both
the intake and exhaust valves to
prevent the inside of the cylinder
from rusting.
5.Clean exterior of the generator and
apply a rust inhibitor.
6.Cover the unit and store in a clean,
dry place that is well ventilated
away from open flame or sparks.
Note:
Using a fuel stabilizer is always recommended. A fuel stabilizer will minimize the
formulation of fuel gum deposits during storage. The fuel stabilizer can be added
to the petrol in the fuel tank, or into the petrol in a storage container.