27
LPP PetRoL GeNset oPeRAtoRs' hANdbook
•
Magneto or electronic ignition system
•
Spark advance / retard system, if applicable
•
Exhaust manifold, if applicable
•
Fuel hoses, connectors and fuel tank cup
The maintenance schedule indicated in the above table is based on normal engine
operation.
Should the engine be operated in extremely dusty condition , in heavier loading
condition or in commercial use, the maintenance intervals must be shortened
depending on the contamination of oil, clogging of filter elements, wear of parts,
and so on.
INsPeCtING the sPARk PLUG
Remove the spark plug and clean the electrodes section with a wire brush or
sandpaper. Next, set the gap (1) at 0.028-0.031 inches (0.7-0.8mm) by adjusting
the negative electrode. Replace the spark plug with correct torque: 14 ft-lb (20 N.m).
Note:
Standard electrode color is tan color.
CAUtIoN
Replace with only the same type of spark plug which was removed. An
improper spark plug can cause the engine to overheat, emit smoke, influence
electromagnetic compatibility of generator or otherwise perform poorly.