LCR.iQ - Setup and Operations Manual
87
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
Options:
·
Products 1-16 are available for setup.
Only setup and calibrate products that are to be
used by the LCR.iQ.
Product code
– A text field for identifying the selected product with a code.The product code
will appear on all ticket formats to identify the product that was delivered, as shown above.
(Maximum - 5 alphanumeric characters)
Product name
– A text field for identifying the selected product with a specific name. The
product name will appear on all ticket formats to identify the product that was delivered as
shown above.
(Maximum - 18 alphanumeric characters)
S1 Close
– A numeric text field that is used with 2 stage preset valves. This value sets the
number based on the unit of measure that will transition a 2 stage valve from high flow to low
flow–for an accurate preset stop. For more information on setting up the S1 closure, see
Setting the S1 Close time
.
(Maximum - 5 alphanumeric characters)
Pulse Output Frequency
– A numeric text field that determines the number of output pulses
per unit of measure when using the calibrated pulse output feature of the LCR.iQ. Setting this
field to 1 will result in a 1:1 pulse output to the unit of measure. The maximum value that can
be set for this field will vary depending on the decimal setting for the unit of measure and the
K-Factor (Pulses/Unit) of the product.
·
Hundredths
- Max 1% of the K-Factor
·
Tenths
- Max 10% of the K-Factor
114