LCR.iQ - Setup and Operations Manual
46
Get the latest PDF manual:
https://www.lcmeter.com/resources/technical/manuals
Mobile/online version of this manual:
https://www.lcmeter.com/manuals
Gross Preset
A numeric text field for the gross preset value–if gross presets are accepted.
(Maximum - 7
numeric characters)
Multiple Deliveries?
A list box in which you can specify if the
Multiple Deliveries
feature is to be on or off. If
Multiple Deliveries
is set to
Yes
, you can fill multiple tanks at one location without being
affected by the
No Flow Timer
feature (see below. This only applies to the next delivery, and
will revert back to
No
automatically when the delivery completes.
If this field is set to
No
, any deliveries will need to be within the value specified in
No Flow
Timer
.
NOTE:
There is also a printer parameter,
Print Multiple Deliveries Per
Site Message in Register 3/3
, that is directly affected by this setting.
No Flow Timer
A numeric-only field for specifying the duration of the
No Flow Timer
. This is an internal timer
that begins when the LCR.iQ senses that there is no longer any product moving through the
meter. If this timer counts up to its set point, the LCR.iQ will assume that the delivery is
complete and a ticker will print automatically. The default value for this field is
180 (seconds)
.
Deactivate this feature by entering 0 seconds, which permits filling multiple tanks at a single
location simultaneously. The timer helps to ensure that deliveries are not split between
authorized and unauthorized locations. If the value is set to 0–or any value greater than 180–
and the
Print Multiple Deliveries Per Site
message is set to
On
, the
Multiple Deliveries At
One Site
message will print on the delivery ticket.
(Maximum - 3600 Seconds)
Net Quantity