Rev: 06.30.22
Page 5
CCD-0001575
Fig. 4
Fig. 3
Brackets
The lift system comes installed with screw-in tab brackets (Fig. 3) affixed to the upper trolleys and/or the
lower trolleys. The slotted lower trolleys can be fitted with hooked tab brackets (Fig. 4) for a lower bed
platform, or hooked brackets with movable arms (Fig. 5) that can accommodate a sofa/dinette configuration.
Fig. 6
Limit Switches
Upper and lower limit switches (Fig. 6A) are located behind the C-channel and secured by two small screws
(Fig. 6B). The limit switches are used to stop the bed(s) at their maximum travel range. However, the lower
bed platform can be stopped and used at any desired height. After the control switch is released, the electric
brake is set — securing the bed(s) in the current position.
B
A
Fig. 5
For the sofa/dinette configuration, sofas should be run to the lower limit switch stop and the sofa support legs
extended before using the sofas.
NEVER sit on or use sofas without sofa support legs extended. Failure to do so may result in personal
injury and/or damage to the bed lift mechanism.
Sofa support legs should not contact the floor prior to the bed lift reaching its lower travel limit.