background image

Rev: 06.30.22

Page 3

CCD-0001575

The "WARNING" symbol above is a sign that a procedure has a safety risk involved and may cause death 

or serious personal injury if not performed safely and within the parameters set forth in this manual. 

Failure to follow instructions provided in this manual may result in death, serious personal injury 

and/or severe product and property damage, including voiding of the component warranty.

Safety

This manual provides general instructions. Many variables can change the circumstances of the instructions, 

i.e., the degree of difficulty, operation and ability of the individual performing the instructions. This 

manual cannot begin to plot out instructions for every possibility, but provides the general instructions, 

as necessary, for effectively interfacing with the device, product or system. Failure to correctly follow the 

provided instructions may result in death, serious personal injury, severe product and/or property damage, 

including voiding of the Lippert limited warranty.

Always wear eye protection when performing service, maintenance procedures. Other safety 

equipment to consider would be hearing protection, gloves and possibly a full face shield, 

depending on the nature of the task.

Moving parts can pinch, crush or cut. Keep clear and use caution.

The "CAUTION" symbol above is a sign that  a procedure has a safety risk involved that may cause 

personal injury and/or product damage, including voiding of warranty, if not performed safely and 

in accordance with the safety procedures stated herein.

Summary of Contents for HAPPIJAC

Page 1: ...HappiJac Bed Lift OWNER S MANUAL...

Page 2: ...12V DC Nominal Current Draw 8 amps 1 bed going up 12 amps 2 beds or 1 bed and 1 sofa dinette configuration going up Load Limit 450 pounds dynamic moving load 600 pounds static stationary load Note Th...

Page 3: ...t out instructions for every possibility but provides the general instructions as necessary for effectively interfacing with the device product or system Failure to correctly follow the provided instr...

Page 4: ...ig 1A Each c channel rail encases a chain drive and trolleys Fig 2 with attached brackets that travel between upper and lower limit switches Fig 1 Fig 2 Upper Trolley A Standard Lower Trolley Slotted...

Page 5: ...ll screws Fig 6B The limit switches are used to stop the bed s at their maximum travel range However the lower bed platform can be stopped and used at any desired height After the control switch is re...

Page 6: ...s above below and adjacent to the bed s are free from obstructions before operating the bed s ALWAYS check before operating bed s to ensure that there is nothing interfering with the travel of the cha...

Page 7: ...ed platform rails Fig 9A are secured to the tab brackets Fig 9B and the bed platform rests on the platform rails Fig 8 A B Note Bed platform has been removed for clarity The upper trolleys can be lock...

Page 8: ...Repeat for the other locking mechanisms A Fig 10 3 Press UP on the control switch until the upper bunk is in the full up position where the bed lift shuts off automatically This will push the upper tr...

Page 9: ...B Fig 12 Lower Trolley Sofa or Dinette Configuration The lift system can be configured to accommodate a bed on the upper trolley and a sofa or dinette on the lower trolleys The sofa or dinette will n...

Page 10: ...em should be set 1 4 to 1 2 higher than the motor side To adjust the timing 1 Press the DOWN switch to lower the bedlift system until it stops 2 Measure from the bottom of the lower trolley sofa brack...

Page 11: ...A Remove the hairpin Fig 18A securing the clevis pin Fig 18B and washer Fig 18C B Remove the clevis pin holding the bedlift rail Fig 18D to the tab bracket Fig 18E C Repeat for the other side 3 Carefu...

Page 12: ...river The sofa dinette brackets can be removed from the lower trolleys and trolley tabs can be added to accommodate a second bed platform See Lower Bunk Trolley Tab Installation for instructions on ad...

Page 13: ...racket can only be installed with the trolley tab at the top 1 Remove the sofa brackets from the lower travel trolley See Lower Trolley Sofa Dinette Bracket Removal 2 Line up the hooks on the edge of...

Page 14: ...tive limit switch Replace limit switch Faulty control module Replace module Faulty UP DOWN switch Replace switch Faulty brake Set manual brake release lever on motor to the OFF position If the bed s m...

Page 15: ...e the Bed s Sofa or Dinettes Resources Required 1 2 Socket and ratchet 1 Unplug the motor harness from the motor port Fig 23A on the PnP control module Note The PnP control module could be mounted in...

Page 16: ...pared to apply the brake if necessary 2 Move brake release lever to OFF position to release Fig 24A Bed will drift downward 3 Re apply the brake when the desired bed height is reached 4 Reconnect the...

Page 17: ...Rev 06 30 22 Page 17 CCD 0001575 Notes...

Page 18: ...e has been provided Any unauthorized use shall void any applicable warranty The information contained in this manual is subject to change without notice and at the sole discretion of LCI Revised editi...