background image

6

Selecting the Mounting Location

 

Select a suitable location for the installation of the module.

 

The module should be installed to reduce the amount of shading.

 

Modules should be mounted as far away from rooftop obstructions (AC units, 
plumbing vents, skylights, etc.) as possible.

 

If solar panels must be installed near rooftop obstructions, try to orient the 
modules with broadside facing the obstruction. This orientation will optimize the 
high by-pass diodes in shaded conditions.

 

When possible, mount solar panels so that the majority of surfaces can be 
oriented south facing if roof is positioned accordingly.

Selecting the Proper Mounting Structure and 
Hardware

 

Observe all instructions and safety precautions included with the mounting 
system to be used with the module.

 

Do not drill holes in the glass surface of the module. Doing so will void the 
warranty.

 

Do not drill additional mounting holes in the module frame. Doing so will void the 
warranty.

 

Modules must be securely attached to the mounting structure using six mounting 
points for normal installation.

 

Load calculations are the responsibility of the system designer or installer. The 
mounting structure and hardware must be made of durable, corrosion-and UV-
resistant materials.

 

Select mounting location such that screw holes on the mounting brackets 
attached to the solar panel frame are aligned with the structural framing of the 
roof. 

Mounting Methods

 

The module mounting structure must be made of durable, corrosion-resistant and 
UV- resistant materials. A Furrion brand Mounting Kit is recommended, Furrion 
model number C-FSFP37MW-A01.

 

In regions with heavy snowfall in winter, select the height of the mounting system 
so that the lowest edge of the module is not covered by snow for any length 
of time. In addition, ensure that the lowest portion of the module is placed high 
enough so that it is not shaded by plants or trees or damaged by flying sand.

 

Modules must be securely attached to the mounting structure.

 

Provide adequate ventilation under the modules in conformity to your local 
regulations. A minimum distance of 4" (100mm) between the roof plane and the 

Summary of Contents for GS-M120-370-FAB1

Page 1: ...370W RIGID SOLAR PANEL MODEL GS M120 370 FAB1 USER MANUAL Product picture for reference only...

Page 2: ...on for safe use installation and maintenance of the product Please keep this instruction manual in a safe place for future reference This will ensure safe use and reduce the risk of injury Be sure to...

Page 3: ...lar Photovoltaic System 5 MECHANICAL INSTALLATION 5 General Installation Notes 5 Selecting the Mounting Location 5 Selecting the Proper Mounting Structure and Hardware 6 Mounting Methods 6 Secure the...

Page 4: ...ons must be read and understood before attempting installation If there are any questions please contact your dealer for further information The installer should conform to all safety precautions in t...

Page 5: ...rrent electrical energy and are designed for outdoor use Proper design of support structures is the responsibility of the system designer and installer Modules may be ground mounted pole mounted or mo...

Page 6: ...articular photovoltaic system Under normal operating conditions PV modules will produce currents and voltages that are different than those listed in the data sheet Data sheet values are applicable at...

Page 7: ...t be securely attached to the mounting structure using six mounting points for normal installation Load calculations are the responsibility of the system designer or installer The mounting structure a...

Page 8: ...ssive forces due to the thermal expansion of the support structures Secure the Solar Panel to the RV Roof 1 Mount the solar panel through the such that at least 4 of the mounting feet have screws pene...

Page 9: ...wiring in the same system The current voltage and power characteristics of the solar panel s will vary based on environmental criteria including temperature and solar irradiance To prevent cables and...

Page 10: ...hey are clean secure undamaged and free of corrosion Remove snow ice or other debris when build up occurs Caution Observe the maintenance instructions for all components used in the system such as sup...

Page 11: ...smission rate and low iron tempered glass 1 8 3 2mm Back TPT Encapsulation material EVA Frame Black Anodized Aluminum Dimension W x H x D 407 8x 691 8 x 13 8 1038 x 1755 x 35mm Weight 40 2lbs 20 5kg C...

Page 12: ...een provided Any unauthorized use shall void any applicable warranty The information contained in this manual is subject to change without notice and at the sole discretion of Lippert Revised editions...

Reviews: