background image

4

lippert.com 

    432-LIPPERT (432-547-7378)   

 

Rev: 08.22.22

Floë

 

838 Integrated 

Water Drainage System

Installation and Owner’s Manual

(For Aftermarket Applications)

CCD-0004086

Fig.5 

1. 

Locate water line entering the home.

NOTE: 

If the main’s water line is under the floor, either drill 

a hole in the floor directly under Floë using a 

1/2

” drill bit 

or locate a vent through which an air line can be fed. Use 

snips or a hacksaw blade to cut an access hole in a vent.

2. 

Turn off the water pump, if installed, and water supply 

shutoff valve.

3. 

Using pipe cutters or shears, cut through water line near 

the water shutoff valve.

NOTE: 

Use a cloth to mop up excess water from the cut 

water line.

NOTE: 

Make sure the ends of pipe are perfectly rounded. 

If adjustment is needed, cover the ends with a cloth and 

use pliers to round the ends.

4. 

Slide both ends of the pipe firmly into the 

1/2

” tee, utilizing 

the tee’s push-fit connections 

(Fig.5)

.

NOTE: 

If larger or smaller pipes are used, adapters can be 

purchased from hardware stores.

NOTE: 

If flexible hose is used for the main’s water, utilize 

the 

1/2

” CTS barbed connectors and hose clamps to create 

connections for the tee. See Figures 10 and 11.

5. 

Measure the distance to connect the air line shutoff 

valve on the Floë unit to the tee installed on the water line.

6. 

Cut air line to length, leaving at least an extra half inch to 

an inch of air line to slide into the connectors.

7. 

Connect air line to both the shutoff valve and to the top 

of the tee fitting 

(Fig.5)

.

Connect to Power Supply

1. 

Plug in Floë to an outlet.

2. 

Use cable tie to hold together excess cord.

NOTE: 

If the cord does not reach an outlet, an extension 

cord may be used.

Test For Air Leaks

At this point Floë has been dry fit. It is worth testing that all 

joints leading up to the main water line are fitted correctly 

without air leaks. Locate the main water line tee and 

remove the barbed connector from the short end of the tee 

leading to the faucets, NOT the water tank long end. The 

barbed connector is removed by pulling back on the collar 

of the tee that holds the barbs in place.

Place a finger into the tee to seal this end and switch on 

Floë. Floë should be tricked into stopping at 15 psi. If Floë 

stops, then the joints leading to the water system are fine. If 

Floë doesn’t stop, then remove, wet and reseat the air line into 

the connectors leading back to Floë. It is essential there is a 

good seal on the open end of the tee to allow this test to work.

Connect Tee Fitting, Hoses

NOTE: 

Floë 115V AC Model 868 is normally used for 

static-built properties. However, it can also be used on 

moving vehicles and boats which, when stationary, are 

connected to an AC supply The application will dictate 

which tee to use, either Fig.5 or Fig.6. If using Floë 868 on 

moving vehicles, consult the fitting instructions for Floë 636 

which is normally used with 12V DC vehicles and boats.

(Fig.5)

 The CTS 

1/2

” one-way single valve tee with equal 

length ends is for use with homes, model homes and any 

other property with a main water supply. It is to be fit as 

close to the main’s water top valve to aid draining the entire 

system. See Operation section.

(Fig.6)

 The CTS 

1/2

” one-way double valve tee with one 

short and one long end is for use with RVs and boats 

where an onboard fresh water storage tank and an electric 

pump is used. Fit tee with long end point toward the water 

tank and the short end toward the filter and pump. See 

fitting instructions for Floë Model 636.

Fig.6 

short side to

filter/pump

long side 

to tank

Summary of Contents for Floe 868

Page 1: ...ons Flo Water Drain Kit Flo Water Drain Kit Part Part Description Description 809128 Model 868 115V AC water drainage system Introduction Flo is a water drainage device that will remove residual water...

Page 2: ...property damage including voiding of the LCI limited warranty THE CAUTION SYMBOL ABOVE IS A SIGN THAT A PROCEDURE HAS A RISK INVOLVED THAT MAY CAUSE PERSONAL INJURY OR PROPERTY DAMAGE IF NOT PERFORME...

Page 3: ...either beside or near the unit NOTE The On Off button on top must be accessible NOTE Toggle bolts or if necessary dry wall rawl plugs can be used if installing the Flo box on drywall NOTE It is not re...

Page 4: ...d may be used Test For Air Leaks At this point Flo has been dry fit It is worth testing that all joints leading up to the main water line are fitted correctly without air leaks Locate the main water l...

Page 5: ...NTENDED USE General Guidelines for Model 868 It is advisable to drain vacation property after most trips in order to maintain a clean fresh water system while also offering frost protection in the win...

Page 6: ...me will happen here but as the water is turned off at the main stop valve or pump switched off in the case of an RV the water to the machine will be limited As other items have been draining the only...

Page 7: ...e feed 1 Turn off all faucets water outlets and irrigation systems to seal the entire system Do NOT flush the toilets 2 Turn off the main water supply shutoff valve 3 Switch on Flo The compressor star...

Page 8: ...n off water Switch on Flo and if motor stops the system is pressurized Flo does not stop or starts and stops continually Malfunction or air leaking from one of the connections Remove the push fit conn...