What is happening?

What is happening?

Why?

Why?

What should be done?

What should be done?

Floë runs beyond two to three 

minutes.

Air leak from toilet.

Switch off Floë, make sure faucets and outlets closed, 

make sure toilets have not been flushed. Listen to toilet tank 

for escaping air. Turn water supply valve by toilet tank to 

horizontal position to turn off water. Switch on Floë and, if 

motor stops, the system is pressurized.

Floë does not stop or starts and 

stops continually.

Malfunction or air 

leaking from one of the 

connections.

Remove the push-fit connection directly under Floë. Switch 

on Floë and hold thumb on stump of air line pipe extending 

out the bottom. If Floë doesn’t stop when thumb is over pipe, 

there may be a malfunction. Contact customer service.
If Floë starts and stops normally with a thumb held on and 

then removed from the air line, the system is OK. Rejoin the 

connector. Work farther downstream to determine the leak, 

including disconnecting the blue shutoff valve and holding a 

thumb over the end of the air line. Remove the black air line 

from the tee fitting and check for leaks using a thumb over the 

air line to ensure connections are sealed.
If the barbed connectors are used with hose water lines, make 

sure they are seated correctly and check to make sure the 

hose clamps are tight. Also, remove water line from tee fitting 

and check that the ends of the pipes are round and not oval 

shaped.
Leaks can also be determined by applying soapy water to the 

joints and watching for bubbles.

Troubleshooting

Summary of Contents for Floe 868

Page 1: ...ons Flo Water Drain Kit Flo Water Drain Kit Part Part Description Description 809128 Model 868 115V AC water drainage system Introduction Flo is a water drainage device that will remove residual water...

Page 2: ...property damage including voiding of the LCI limited warranty THE CAUTION SYMBOL ABOVE IS A SIGN THAT A PROCEDURE HAS A RISK INVOLVED THAT MAY CAUSE PERSONAL INJURY OR PROPERTY DAMAGE IF NOT PERFORME...

Page 3: ...either beside or near the unit NOTE The On Off button on top must be accessible NOTE Toggle bolts or if necessary dry wall rawl plugs can be used if installing the Flo box on drywall NOTE It is not re...

Page 4: ...d may be used Test For Air Leaks At this point Flo has been dry fit It is worth testing that all joints leading up to the main water line are fitted correctly without air leaks Locate the main water l...

Page 5: ...NTENDED USE General Guidelines for Model 868 It is advisable to drain vacation property after most trips in order to maintain a clean fresh water system while also offering frost protection in the win...

Page 6: ...me will happen here but as the water is turned off at the main stop valve or pump switched off in the case of an RV the water to the machine will be limited As other items have been draining the only...

Page 7: ...e feed 1 Turn off all faucets water outlets and irrigation systems to seal the entire system Do NOT flush the toilets 2 Turn off the main water supply shutoff valve 3 Switch on Flo The compressor star...

Page 8: ...n off water Switch on Flo and if motor stops the system is pressurized Flo does not stop or starts and stops continually Malfunction or air leaking from one of the connections Remove the push fit conn...