TME-104P-CSR-LX800-R1V11.doc
Rev 1.11
36 (50)
The
Serial and Parallel Device Configurations
menu allows configuring COM1, COM2 and LPT.
COM-Ports can be switched between RS232 and RS485. It is possible to change the resource and interrupts of all
ports.
Hard Drive Setting
Options
Serial Port 1/2
Disabled, 0x3f8 IRQ 4, 0x2f8 IRQ 3,
0x3e8 IRQ4, 0x2e8 IRQ3
Serial Mode
RS232, RS485
Parallel Port
Disabled, 0x378, 0x278, 0x3BC
Parallel Mode
Compatible, PS/2 Bi-directional,
EPP 1.7, EPP 1.9, ECP
Parallel IRQ
Disabled, IRQ5, IRQ7, IRQ9, IRQ10, IRQ11
Parallel DMA
Channel 1, Channel 3