Flow Max

 12V DC 

Fluid Pump 

by Duraself

Installation and Owner’s Manual

(For Aftermarket Application)

Introduction

Parts List

The Flow Max

 Fluid Pump by Duraself (Model Number: 

DS-01233-D) delivers smooth, consistent flows at all 

ranges of operation while drawing low current. The motor 

design incorporates ball bearings for long life and the 

motor is equipped with an integral thermal breaker. The 

RV/marine duty pump has sealed switches and is finished 

with electrocoating to inhibit corrosion. The pump is also 

enclosed to prevent incidental moisture from entering.
The Flow Max Fluid Pump is capable of self-priming up 

to 6 vertical feet and can run dry. The pump is designed 

for intermittent duty only. Do not use the pump for running 

a Reverse-Osmosis (RO) Filtration System. Continuous 

running under higher pressure may reduce pump life. 

There are no replaceable parts for the pump.
For safety, it is recommended that power to the pump is 

shut off when leaving the unit unattended.

THE “WARNING” SYMBOL ABOVE IS A SIGN THAT 

AN INSTALLATION PROCEDURE HAS A SAFETY RISK 

INVOLVED AND MAY CAUSE DEATH OR SERIOUS 

INJURY IF NOT PERFORMED SAFELY AND WITHIN THE 

PARAMETERS SET FORTH IN THIS MANUAL. ALWAYS 

WEAR EYE PROTECTION WHEN PERFORMING 

THIS INSTALLATION PROCEDURE. OTHER SAFETY 

EQUIPMENT TO CONSIDER WOULD BE HEARING 

PROTECTION, GLOVES, AND POSSIBLY A FULL 

FACE SHIELD, DEPENDING ON THE NATURE OF THE 

INSTALLATION PROCEDURE.

MOVING PARTS CAN PINCH, CRUSH OR CUT. KEEP 

CLEAR AND USE CAUTION.

 B

 A

Letter

Part# Description

Qty

A

689052

Flow Max Fluid Pump

1

B

689059

Screen Filter and Connectors

2

Summary of Contents for 689052

Page 1: ...ion Table of Contents Introduction 2 Parts List 2 Resources Required 3 Installation 3 General Installation Instructions 3 Mounting Instructions 3 Plumbing The System 4 Electrical Connections 5 Sanitiz...

Page 2: ...designed for intermittent duty only Do not use the pump for running a Reverse Osmosis RO Filtration System Continuous running under higher pressure may reduce pump life There are no replaceable parts...

Page 3: ...mal breaker and interrupt operation When the temperature drops the breaker will automatically reset 4 Pump may be mounted in any position However if pump is mounted vertically the pump head should be...

Page 4: ...ve fittings and connections e g elbows T s and feeder lines to faucets To reduce rapid cycling the pump shutoff pressure switch setting Fig 3 can be increased by turning the screw clockwise 1 1 2 turn...

Page 5: ...eeded to sanitize the tank 2 Mix the bleach with water in a container 3 Pour the bleach solution into the tank and fill the tank with potable water 4 Open all faucets hot and cold and allow water to r...

Page 6: ...water tank NOTE If the tank doesn t have a drain valve open all faucets while allowing the pump to operate 15 minutes on 15 minutes off until the tank is empty 2 Open all the faucets including the low...

Page 7: ...in faucets shower heads Ensure water filter purifier is on separate line feed Check if pressure switch shutoff needs adjustment Pump Will Not Shut Off Runs When Faucet Closed Check output side pressur...

Page 8: ...cument only unless Lippert Components provides explicit consent to distribute individual parts All manual information is subject to change without notice Revised editions will be available for free do...

Page 9: ...Table des mati res Introduction 2 Liste de pi ces 2 Outils requis 3 Installation 3 Instructions g n rales d installation 3 Instructions de montage 3 Plomberie du syst me 4 Connexions lectriques 5 Assa...

Page 10: ...e de service intermittent seulement Ne pas utiliser la pompe sur un syst me de filtration osmose inverse Le fonctionnement continu pression lev e peut r duire la dur e de vie de la pompe La pompe n es...

Page 11: ...nnement Une fois le moteur refroidi le sectionneur se r enclenchera automatiquement 4 La pompe peut tre install e dans toutes les positions Toutefois si elle est install e verticalement la t te de la...

Page 12: ...as sur des conduites d alimentation s par es Les r ducteurs de d bit des robinets et des t tes de douche Les conduites ayant un faible diam tre int rieur Les raccords et connexions restrictifs comme l...

Page 13: ...llisante dans le r servoir et remplir le r servoir d eau potable 4 Ouvrir les robinets eau chaude et froide et laisser l eau couler jusqu ce que l odeur de chlore soit d cel e Fermer ensuite les robin...

Page 14: ...erie Fermer ensuite la pompe 3 En utilisant un bac pour recueillir l eau restante retirer les tuyaux aux orifices d entr e et de sortie de la pompe 4 Ouvrir la pompe et la faire fonctionner jusqu ce q...

Page 15: ...sserr es Succession de cycles rapide V rifier les restrictions au niveau de la plomberie et du d bit des robinets et t tes de douche S assurer que le filtre d eau et le purificateur se trouvent sur un...

Page 16: ...able un consentement explicite de la part de Lippert Components pour distribuer des parties individuelles Tous les renseignements contenus dans le pr sent manuel peuvent tre modifi s sans pr avis Les...

Reviews: