Instructions
Compact disc mower KSM 130
15 - 22
140050-01-EN BA KSM 130 / 04.06.2020
Replacement of the blade holders
•
The continuous movement of
the blade will cause the bolt to
become worn. If the hole of a
new blade reaches to the edge
of the cutting disc and is visible
from above, the blade holder
must be replaced immediately.
In this case, the bolt diameter
is worn out to about 30%. To
replace the blade holders, the
disc must be unscrewed.
(Fig. 4)
Before each use for mowing and after each replacement of the
blades, the blade holders must be checked for wear.
•
For reasons of safety, use
LIPCO original spare parts
only.
Lubrication
•
The cardan joint must be
lubricated via the lubricating
nipples especially provided for
this purpose (Fig. 5).
•
Drive flange: Lubricate once a month and turn it
– must run
smoothly when turning. (see Fig. 1 - E)
•
Remove drive flange once a year, clean it to remove dirt and
regrease it.
Fig. 4
Fig. 5
Lubricating nipple
Summary of Contents for KSM 130
Page 22: ...22 22 Design mail bauer ib com...