background image

11

TrainMaster Command operations

The Command Control environment

T

rainMaster Command Control is the
advanced model railroad control system

from Lionel that gives you the power to operate
multiple Command-equipped locomotives 

on

the same track, at the same time. 

To operate in Command mode, you

need a Command Base (6-12911)
and a CAB-1 Remote Controller 
(6-12868).

Find them both at your

authorized Lionel retailer.

Place your locomotive set on Lionel or 
Lionel-compatible O-42 or larger track.

2

2

Address your locomotive set using your CAB-1 Remote
Controller.

To operate your locomotives together as a lash-up, 

press 

TR

and 

9

on

your CAB-1 Remote Controller. Be sure that the powered unit is in the lead. Refer
to page 16 for information about TrainMaster Command Control lash-ups.

To operate your engines individually, 

address the powered unit by

pressing 

ENG

and 

1

on your CAB-1 Remote Controller. Address the non-powered

unit by pressing 

ENG

and 

2

on your CAB-1 Remote Controller.

The digital language of TrainMaster Command Control—not track
power—controls the actions of Command-equipped Lionel
locomotives. 

Track power is simply like gasoline in the tank of your car—it

gives you the power to go places, but it doesn’t tell you where to go or how fast to
get there.

Your powered locomotive was assigned 

ENG 1

and your non-powered

locomotive was assigned 

ENG 2

at the factory. They have already been

programmed as a lash-up, 

TR 9

. You may change these settings at any

time with the help from the following sections in this manual.

3

3

Move ‘em out!

• 

Throttle up or press any command button on the CAB-1 Remote
Controller.

Your locomotive set will respond to your every command.

1

1

• 

Make sure track power is OFF before placing on the track.

• 

Make sure your Lionel Command Base is plugged-in 

and its

communications wire is connected to the COMMON post on your Lionel
transformer 

or 

the U terminal on any of your installed PowerMasters.

•  Once positioned on the track, 

increase track voltage to FULL 

(no more

than 19 volts). On PowerMasters, slide the CMD/CONV switch to CMD.

Note!

Summary of Contents for ALCo PA A-A Diesel Locomotive Set

Page 1: ...Lionel ALCo PA A A Diesel Locomotive Set Owner s Manual 71 4571 250 8 03 SYSTEM featuring and...

Page 2: ...ilSounds sound system with CrewTalk communication and TowerCom announcements in Command Odyssey System for speed control Directional lighting including operating headlights Operating Mars light Die ca...

Page 3: ...entional transformer operation 10 Odyssey System Command operation 10 TrainMaster Command operations The Command Control environment 11 Running your powered locomotive in the TrainMaster Command Contr...

Page 4: ...t Virtually all Lionel and Lionel compatible alternating current transformers are suitable Do not power your locomotive set with direct current DC Damage to sensitive electronic components may occur W...

Page 5: ...e locomotive set is now locked into your chosen direction When you no longer want single direction operation just slide the Command reverse unit switch back to RUN Your locomotive s reverse unit will...

Page 6: ...ted by a Lionel Remote Control Track section available separately 6 65530 for O gauge 6 65149 or 6 12746 for O 27 gauge and 6 12020 for FasTrack layouts Place your rolling stock s coupler trigger disc...

Page 7: ...e nut Red wire Red wire The no 610 5906 001 button works with any Lionel AC transformer except no 6 4690 Type MW Transformers made by other manufacturers may not be compatible with the RailSounds soun...

Page 8: ...life diesel locomotives for the ultimate in realism You may choose to install a nine volt alkaline battery in the powered locomotive set This ensures interruption free operation of the RailSounds sou...

Page 9: ...sound system in the world Four diesel roar levels Your locomotive set s speed automatically determines the level of diesel RPM roar If you prefer you may set the level to idle half throttle three quar...

Page 10: ...onnected directly to track power Do not exceed 14 16 volts for extended periods Doing so will cause damage to the locomotive Odyssey System operations Odyssey System conventional transformer operation...

Page 11: ...sing ENG and 2 on your CAB 1 Remote Controller The digital language of TrainMaster Command Control not track power controls the actions of Command equipped Lionel locomotives Track power is simply lik...

Page 12: ...unds Press HALT to shut down all PowerMaster electrical output on your railroad Stops all Command equipped Lionels in operation Turn the THROTTLE to the right to accelerate left to decelerate CAB 1 Re...

Page 13: ...ommences 4 Lowers the volume of the RailSounds sound system Sound volume decreases 5 Activates the RailSounds sound system shutdown sequence Just like the real thing your locomotive set s RPMs must be...

Page 14: ...gure 3 on page 8 for the location Turn the adjustment knob left or right to reach the desired volume level For quick remote control of volume below the master setting for example muting use the CAB 1...

Page 15: ...wered locomotives have been factory programmed as a lash up both units must have their own ID s This allows you to open the appropriate ElectroCouplers and set the appropriate directional lighting The...

Page 16: ...Command reverse unit switches must be set to RUN FORWARD If you press a wrong button start over with that particular unit the assignment isn t saved until you press SET on the CAB 1 Remote Controller...

Page 17: ...the following steps STEP 1 Move the switch on your locomotive from RUN to PRGM STEP 2 Plug in your Command Base STEP 3 Place the locomotive on track then turn on power to your track STEP 4 Press ENG t...

Page 18: ...duction decreases add four to eight drops of smoke fluid in the same manner Additional smoke fluid 6 62909 is available from your Lionel dealer To turn off the smoke generators slide the SMK NO SMK sw...

Page 19: ...otive set requires lubrication when visual inspection reveals dryness on the parts indicated in Figures 5 and 6 Remove accumulated dirt and dust before lubricating and always lubricate any locomotive...

Page 20: ...set Lubricating your locomotive set continued FRONT Non Powered Unit Figure 6 Lubricating the non powered unit Lubricate axles with Lionel oil sparingly Lubricate axles with Lionel oil sparingly Body...

Page 21: ...ctive effort of the unit allowing it to pull more cars at once During the course of normal operations the traction tires may become worn out Because you must remove the trucks and the side frames to a...

Page 22: ...ps During the course of normal operations the LEDs and lamps may require replacement Due to the delicate wiring and soldering operations we recommend that you have the replacement done at a Lionel Ser...

Page 23: ...Notes 23...

Page 24: ...from state to state Instructions for Obtaining Service If service for this Lionel L L C product is required bring the item along with your dated sales receipt and completed warranty information to the...

Reviews: