Installation Guide Power Supply
DE
Page 8 / 12
Power range 480 W
NTI AG / LinMot
7.2 Current limiting characteristics (typ.)
7.3 Derating
7.4 Remote ON/OFF
Connecting an external DC source:
Connect positive pole of the DC source to pin 4. Connect negative
pole (GND) of the DC source to the negative output connector of the
S01-500. Adjust 5V.