1  General information 

1.1  Introduction 

Please observe the following safety instructions, the instructions on the appliance (the term "appliance" 
relates to a single power supply assembly) and the detailed data sheet to avoid any risk of personal injury or 
damage to the appliance or to other equipment which may be connected. 

1.2  Explanation of symbols 

 

Triangular warning symbols warn against a danger. 

 

 

Round command symbols tell what to do. 

1.3  Qualified personnel 

All work such as transport, installation, commissioning and service is only allowed to be carried out by 
qualified personnel. Qualified personnel in the sense of the safety instructions in this documentation are 
persons who are familiar with the transport, installation, assembly, commissioning and operation of the 
product and who have the appropriate qualifications. 
This manual must be read carefully before transport, installation, commissioning, service and all safety-
related information must be adhered to. 

1.4  Liability 

NTI AG (as manufacturer of LinMot linear motors and MagSpring products) excludes all liability for damages 
and expenses caused by incorrect use of the products. This also applies to false applications, which are 
caused by NTI AG's own data and notes, for example in the course of sales, support or application activities. 
It is the sole responsibility of the user to check the information and information provided by NTI AG regarding 
their safety-relevant correctness. In addition, the entire responsibility for safety-related product functionality 
lies exclusively with the user.Product warranties are void if products are used with stators, sliders, servo 
drives or cables not manufactured by NTI AG unless such use was specifically approved by NTI AG. 
NTI AG’s warranty is limited to repair or replacement as stated in our standard warranty policy as described 
in our "terms and conditions" previously supplied to the purchaser of our equipment (please request copy of 
same if not otherwise available). Further reference is made to our general terms and conditions. 

1.5  Copyright 

This work is protected by copyright. 
Under the copyright laws, this publication may not be reproduced or transmitted in any form, electronic or 
mechanical, including photocopying, recording, microfilm, storing in an information retrieval system, not even 
for training purposes, or translating, in whole or in part, without the prior written consent of NTI AG. 
LinMot® is a registered trademark of NTI AG. 

 

 

Summary of Contents for S01-24/500

Page 1: ...NTI AG LinMot Dok Nr 0185 1112 E_2V0_IG_Power_Supplies_S01_500 Installation Guide Power Supply ENG Power range 480 W Typ S01 24 500 Typ S01 72 500 ...

Page 2: ... 2 Safety instructions 4 3 Technical Data 5 4 Operating data 6 5 Mechanics 6 5 1 Connection 6 5 2 Mounting 7 6 Explanation of symbols 7 7 Notes 7 7 1 DIP switch position 7 7 2 Current limiting characteristics typ 8 7 3 Derating 8 7 4 Remote ON OFF 8 8 Dimensions 9 9 International Certificates 9 9 1 UL Listing 9 9 2 UL Recognized Component 9 10 Declaration of Conformity and CE marking 10 11 CB Test...

Page 3: ...ges and expenses caused by incorrect use of the products This also applies to false applications which are caused by NTI AG s own data and notes for example in the course of sales support or application activities It is the sole responsibility of the user to check the information and information provided by NTI AG regarding their safety relevant correctness In addition the entire responsibility fo...

Page 4: ...iance To ensure safe performance and avoid any possible risk of damage to the assembly itself and or connected equipment provision must be made for adequate heat dispersal Please observe the relevant instructions in this document and the appliance Please take note of the information shown on the connection and pin configurations for this appliance Pay particular attention to the information on the...

Page 5: ...Vss typ Temperature coefficient 0 025 K Switch on switch off No Vo overshoot soft start Start up delay 1 5s at 230VAC Rise time 40 ms typ 80 ms typ Back feeding voltage up to 35Vdc up to 100 Vdc Serial connection yes max 2 identical power supplies Parallel connection yes only in parallel mode max 3 identical power supplies Regulation Line regulation 0 2 for Vo at Vimin Vimax Load regulation 0 5 fo...

Page 6: ...4 Industrial generic standard EN 55011 Class B Radiation depends on assembly Weight 1 0 kg 4 Operating data Temperature range 25 C 70 C integral temperature regulated fan sucking in air from below Derating 3 K at 60 C see diagram chapter 7 Due to the integrated fan the SPH500 can be installed in any position The passage of air must not be obstructed by installation The distance to the air vents mu...

Page 7: ...the air inlets and outlets and the surrounding devices Please ensure that the air extracted is not immediately sucked in again 6 Explanation of symbols Protective Earth Do not use supply without PE connection L1 N Mains phase neutral conductor PE Functional Earthing Loadoutput Vo Relay OK FAIL Monitoring connections Control signal OFF External on off DIP switch Selection boost and parallelmode UP ...

Page 8: ...TI AG LinMot 7 2 Current limiting characteristics typ 7 3 Derating 7 4 Remote ON OFF Connecting an external DC source Connect positive pole of the DC source to pin 4 Connect negative pole GND of the DC source to the negative output connector of the S01 500 Adjust 5V ...

Page 9: ...Installation Guide Power Supply DE NTI AG LinMot Power range 480 W Page 9 12 8 Dimensions in mm 9 International Certificates 9 1 UL Listing 9 2 UL Recognized Component ...

Page 10: ...150 2480 Schaltnetzteil 72V 500W 1x120 230VAC 0150 1874 konform ist mit den Anforderungen der Richtlinien is conform to the provisions of directives est conformé aux exigences des directives 2014 35 EU LVD 2014 30 EU EMCD gestützt auf die folgenden Normen based on the following standards base aux normes suivants EMCD EN61000 6 2 2005 EN61000 6 3 2007 A1 2011 SAFETY IEC 60950 1 2005 second edition ...

Page 11: ...Installation Guide Power Supply DE NTI AG LinMot Power range 480 W Page 11 12 11 CB Test Certificate ...

Page 12: ...kerstrasse 2 CH 8957 Spreitenbach Sales Administration 41 0 56 419 91 91 office linmot com Tech Support 41 0 56 544 71 00 support linmot com Tech Support Skype skype support linmot Fax 41 0 56 419 91 92 Web http www linmot com LinMot USA LinMot USA Inc N1922 State Road 120 Unit 1 Lake Geneva WI 53147 Sales Administration 262 743 2555 E Mail usasales linmot com Web http www linmot usa com ...

Reviews: