Installation Guide Linear Motors
ENG
Page 32 / 40
P01-48 EX protected
NTI AG / LinMot
PS01-48x360F-EX-E-FC (0150-1300)
/ Phase1-
Red / Pink
Pin A / Pin B
1.5
/ Phase2-
Blue / Grey
Pin C / Pin D
1.5
5V / GND
White / Inner shield
Pin 1 / Pin 2
155
Sensor Sine / GND
Yellow / Inner shield
Pin 3 / Pin 2
33 k
Sensor Cosine / GND
Green / Inner shield
Pin 4 / Pin 2
33 k
Temp. Sensor / GND
Black / Inner shield
Pin 5 / Pin 2
10 k
Phase / GND
-
Pin 1 - 4 / Pin 2
> 20 M
All Pin / Shield
-
Pin A - 10 / Housing
> 20 M
Kty 1
-
Pin 7, 8
580
@ 20 °C
Kty 2
-
Pin 9, 10
580
@ 20 °C
7 Storage, transport, installation height
•
Sliders are to be stored and transported only in the plastic containers (with cardboard inlay) provided for
this purpose, or already installed and secured in LinMot P stators.
•
Remove the slider from this plastic containers only for assembling.
•
The storage area must be dry, dust-free, frost-free and vibration-free.
•
Maximum relative humidity: 60 %.
•
Prescribed storage temperature: -
15 °C…70 °C
•
The motor must be protected against extreme weather conditions.
•
The air in the storage area must not contain any harmful gases.