Installation Guide Linear Motors
ENG
Page 28 / 40
P01-48 EX protected
NTI AG / LinMot
4.8.3 Determination of water pressure
Δp
Example
Q
Water
:
0.7 l / min
➔
Δp = 1.8 bar
The required water pressure to inject the required water flow depends on the hydraulic resistance of the
cooling circuit.
4.8.4 Corrosion protection
It is advised to add a corrosion protection into the cooling medium (water). A suitable agent can be, for
example, Protectogen C Aqua by Clariant. Information of the mixing ratio between the cooling medium and
the corrosion protection agent can be taken from the manufacturer's instructions.
•
Mixing of various corrosion protection agents is to be avoided.
•
Corrosion protection products must be matched to the materials of the cooling circuit.
•
The cooling system consists of copper tubing.
4.8.5 Cooling line connection
Two threaded connections are used for the inflow and outflow of the cooling medium to and from the stator
(see illustration above). The connection can be implemented as an M5 thread.
Internal thread M5 x 5
Port cross section-Ø D = 3 mm
Summary of Contents for 0150-1299
Page 35: ...Installation Guide Linear Motors ENG NTI AG LinMot P01 48 EX protected Page 35 40 ...
Page 36: ...Installation Guide Linear Motors ENG Page 36 40 P01 48 EX protected NTI AG LinMot ...
Page 37: ...Installation Guide Linear Motors ENG NTI AG LinMot P01 48 EX protected Page 37 40 ...
Page 39: ...Installation Guide Linear Motors ENG NTI AG LinMot P01 48 EX protected Page 39 40 ...