Linkam Scientific Instruments CCR1000 User Manual Download Page 5

 

 

Safety Precautions 

 
1) 

Read this guide before using the equipment.  Save these instructions for later use. 

2) 

Follow all warnings and instructions which may be placed on the programmer or stage. 

3) 

If for any reason the mains fuse needs to be replaced then it must be replaced by one of the same 

 

type and rating as shown in the equipment ratings. 

4) 

To prevent electric shock, do not remove the cover of the controller or associated electronics. 

5) 

Never use the equipment if a power cable has been damaged. Do not allow any heavy objects to 

 

rest on the power cables.  Never lay the power cables on the floor.  

6) 

Do  not  obstruct  any  ventilation  holes.    Do  not  attempt  to  insert  anything  into  these  openings.  

 

Provide adequate ventilation of at least 75mm all around the equipment. 

7) 

Do not expose the equipment to water.  If for any reason it gets wet then unplug it from  the  mains 
and contact Linkam Scientific Technical Support. 

8) 

The equipment is not intended to be used outdoors

9) 

Each  product  is  equipped  with  a  3-wire  grounded  (earth)  mains  plug  or  a  free-end  3  wire 

 

mains  lead.  The  plug  only  fits  into  a  grounded-type  outlet.  The  free-end  mains  lead  should  be 

 

connected to a correctly grounded 3-wire mains outlet. Do not defeat the purpose of the grounded 

 

(earth) type plug. 

 

 

Free - end mains leads are colour coded as follows : 
 
 

 

Colour   

 

Function 

 

 

Brown   

 

Live 

 

 

Blue 

 

 

Neutral 

 

 

Green/Yellow 

 

Earth (Ground) 

 
10) 

If any problems occur then unplug the equipment from the mains outlet and contact Linkam Sci-

 

entific Technical Support. 

11) 

Do  not  remove  the  cover  from  the  equipment  unless  the  mains  inlet  has  been  removed.    Any 

 

servicing should be carried out by qualified service personnel. 

 

Symbol Reference 

 

Caution: 

 
This safety symbol is on the back panel of the equipment and warns:- 
The user must not make or remove any connections while the unit is powered on. 
To avoid electric shock do not remove the cover.  Refer servicing to qualified service personnel. 

 

Caution:

 

 
This warning symbol indicates that the surface labelled with this symbol may be hot. 
 

 

Feedback:  

Your feedback will be greatly appreciated, please go to 

www.linkam.co.uk

 to fill in the Feedback form. 

Summary of Contents for CCR1000

Page 1: ...CCR1000 Catalyst Cell Reactor Linkam Scientific Instruments USER GUIDE...

Page 2: ...cope with Dovetail Substage 7 Set Up the CCR1000 8 Electrical Cable Connectors 8 Connection to T95 System Controller 9 Connect the ECP Water Circulator Pump 10 Connect the Gas Lines 10 Pressure Warnin...

Page 3: ...with us to Activate your warranty and technical support Access the online setup videos Permanently unlock the Linksys32 software if purchased If you have purchased Linksys32 software please install t...

Page 4: ...isuse operation outside of the environmental specifications for the product or improper site preparation or maintenance Technical Support Any technical questions or queries should be addressed to the...

Page 5: ...oors 9 Each product is equipped with a 3 wire grounded earth mains plug or a free end 3 wire mains lead The plug only fits into a grounded type outlet The free end mains lead should be connected to a...

Page 6: ...y porous ceramic cloth filter Gas is introduced via a high pressure valve and is then heated by sample holder before passing through the sample A high pressure outlet valve can be connected to various...

Page 7: ...base of the stage using the supplied hex screws and the outer most holes in the base plate Adjust the two positioning screws 1 and the thumb screw 2 so that approximately 5mm of thread is exposed on...

Page 8: ...d with the CCR1000 1 CCR1000 2 Green Temperature Sensor Cable 3 Power Cable 4 Stage Connection Lead Electrical Cable Connectors Plug in the green Temperature Sensor cable to stage Make sure the and ma...

Page 9: ...95 System Controller From the stage connect the green Temperature Sensor cable to the Stage Socket 1 and connect the Stage Connection Lead to Stage Connection Socket 2 Refer to the T95 LinkPad Manual...

Page 10: ...ocate the gas line and connector into the stage body No force is necessary Now screw in the connector until it stops using only fingers No spanner is necessary unless using stainless steel tubing Note...

Page 11: ...Holder 2 The next step requires great care and minimal force Once the tool is axially aligned with the sample holder it will need to be pressed over the outer diameter of the Sample Holder Rotate the...

Page 12: ...ment Turn the Sample Holder upside down and with a forefinger and thumb gently rest it over the alu mina silica fabric 1 Once the sample holder is in position apply a very light force and rotate the s...

Page 13: ...to the central hole in the sample loading base until resistance is felt Excessive forces are not needed as the sample holder should slide into the sample loading base Place the Sample Loading Funnel 3...

Page 14: ...Holder into the heater assembly Rotate the sample holder to make sure that it is axially aligned with the heater assembly Once the sample holder is positioned in the heater assembly place a fore finge...

Page 15: ...nt Spares Kit CCR SLK Sample Loading Kit CCR CC Ceramic Cloth for Sample Loading 6x3 5cm x4 CCR CPF Cole Palmer Fitting with Ferrule x4 W22Q1 22mm Diameter Quartz Window 1mm thick x2 CCR ALSH Alumina...

Page 16: ...am Scientific Instruments Ltd Tel 44 0 1737 363 476 Fax 44 0 1737 363 480 Email support linkam co uk Unit 8 Epsom Downs Metro Centre Waterfield Tadworth Surrey KT20 5LR UK www linkam co uk Version 1 0...

Reviews: