-35-
Trigger Action
Select the trigger action
■
Buzzer
The buzzer sounds for about 0.3 seconds
■
Stop measurement
Select how long the measurement continues after the trigger matching.
Quick
:
Immediately stops
measurement
Before
:
Record 64KB of data
after the trigger
matching and then
stops measurement.
Center
:
Record until the half
of capture buf fer
and then stops
measurement.
After
:
Record a lot of data after the trigger matching. (At least 64KB of
data before trigger matching is saved.)
■
Save data
It saves the measured data
before the trigger point (offset -)
/ after the point () for the
specified amount(set value x 32
bytes) to the storage device as a
"TGSAVEnn.DT" file
*1
.
While it saves data, the next saving operation is ignored. If the measurement
stops during the saving process, that file is not saved.
Since one frame is recorded by a variable length of 32 bytes to 384 bytes,
when you want to save it including the frame where the trigger matches set
"Offset-" to 12 or more. Also, set a large value for "". As the last saved
frame can be in the middle of the frame, it may be displayed as "Lost data"..
* 1 :
File name “nn” is automatically named with 00 to 99. After 99, it will overwrite
the file and go back to 00. Once the measurement ends, it will start over from 00