-10-
Color of the
lead wire
Signal
Meaning
red
Vbat
Battery power supply
(
9V
~
18V
)
blue
LIN Bus LIN bus signal
black
GND
Signal ground
<
For LIN
>
Pick the target signals using the IC clips of 3-line probe cable. The
correspondence of the lead wires and I/O signals is described below.
3-line Probe cable
Supply
:
Vbat from external device.
(
analyzer does not supply)
<
External and trigger I/O
>
The analyzer has the external I/O terminals besides the interfaces of CAN/CAN
FD and LIN.
They are for analog/digital input and the trigger I/O. Use the attached 8-line
probe cable.
⑦ ⑤ ③ ①
⑧ ⑥ ④ ②
Pin number
Signal
Description
1
IN4
Digital/Analog input4
2
GND
Signal ground
3
IN2
Digital/Analog input2
4
IN3
Digital/Analog input3
5
TRG OUT Trigger output
6
IN1
Digital/Analog input6
7
TRG IN
Trigger Input
8
GND
Signal ground