40
VBUS Measurement
Accuracy
Voltage: range 0 to 8V, Accuracy ±1%FS
Current: range -0.9A*2 to 1A, Accuracy ±1%FS
VBus measurement
Bar
Display (or do not display) VBus measurement Bar.
VBus
logger
mode
Measurement
Cycle
100ms - 1s (4 steps)
0.1ms – 1s (13 steps)
Storage
Capacity
HDD/SSD: Max.2GB
*Automatically stop measurement on getting the data of 400,000,000
sampling(2Gbytes) from the beginning of measurement.
Graph
display
Display voltage, current, and power consumption in graph at real time.
Dump
display
Display voltage, current, and power consumption in dump display at
real time.
Save
Save log file data, export in text/CSV/binary for data payload, copy/
paste via a clipboard. (Able to make comments on saved data.)
*VBus logger mode has only the function of saving log files and CSV
outputting.
Print function
Specified ranges of recorded data can be printed.
*VBus logger mode does not have this function.
Measurement port
USB standard A/B receptacle: 1 each
USB2.0 port
USB standard B receptacle, Connect to the analysis PC
LED Indicator
2-colored LED, POWER/RUN, VBUS, DATA, SPEED (High:red,
Full:green)
Power Supply
USB Bus power (current consumption: 400mA max)
Ambient Temperature In operation: 0 to 40°C
In storage: -20 to 60°C
Ambient Humidity
In operation: 20 to 80%RH
In storage: 20 to 85%RH (No condensation)
Standard
CE(class A)
Dimensions, weight
86(W)×130(D)×30(H)mm, approx.210g
System Requirement
OS: Windows® 7(32/64bit)/8.1(32/64bit)/10(32/64bit) (Japanese/
English Windows®)
CPU: Recommend to use upper model than "Core i series"
RAM: More than 1GB. USB port: USB2.0
Additional Memory: HDD or SSD. 30MB plus enough capacity to
record log data.
*1: Bus Reset, Suspend, Disconnect are recorded under the following condition.
Bus Reset
The SEO status of D+/D- signals is detected within a range between 2.5us and 139.8ms
Suspend
A non-communication period not in the SEO status is detected for 3ms or over.
Disconnect
The SEO status of D+/D- signals is detected for 139.8ms or over.
Note: The USB device status may not coincide with the actual bus state of the applicable device at the time of
USB cable connection or disconnection because the D+/D- signals will be unstable.
*2: Display a minus value when VBUS current flows from the device to the host.