background image

7

dc2259af

DEMO MANUAL DC2259A

prevents any voltage drop errors caused by the discharge 

current flowing through the cell interconnection wiring. An 

accurate indication of the true cell voltage is then obtained.
The LTC6811 offers the option of keeping the discharge 

transistors steadily on while measuring the cell voltages. 

This is done using the STARTCELL DCC command button. 

The command button is illuminated blue when this com-

mand has been executed. This lower voltage reading also 

includes I•R errors introduced by cabling and connectors.

6. Other Control Features

Additional command buttons are provided on the control 

screen. The POLL ADC command button is used to test 

if the ADC is busy making conversions of any LTC6811 

devices in a system. The result of this command can be 

observed by monitoring the serial data output line of the 

SPI interface to the Bottom Port, J2. There is no indication 

provided on the control screen.
The START OPEN (WIRE) command button connects 

the built-in open wire detection circuitry to all cells. This 

command must be followed by any command buttons 

inside the READ CELLS box click to see the result. The 

OPEN WIRE TEST CURRENT box provides options to use 

either PULLUP or PULLDOWN Open Wire Test Currents. 

An open wire connection to any cell will be indicated by an 

abnormally high voltage measurement for the cell above 

the open wire and a near zero measurement for the cell 

with the open wire in the PULLDOWN case. 

7. Continuous Operation

OPERATING THE CONTROL SCREEN

For convenience, the control panel allows for continuous 

operation of the DC2259A board. When the command 

button labeled START CONTINUOUS READ CELLS is se-

lected, the GUI operates in a continuous loop executing 

the following command sequence automatically:

Start cell voltage

Read cell voltage groups A (1 – 3) , B (4 – 6), C (7 – 9), 

and D (10 – 12)

Read flags

Options available are the READ DISPLAY box, ADC SETTINGS 

box, OPEN WIRE TEST CURRENT box, and the CONTINU-

OUS box. The CONTINUOUS box allows the selection of 

STARTCELL, STARTOPEN, STARTCELL DCC, and STAR-

TOPEN DCC commands to be executed during continuous 

operation. The options are useful for monitoring the cell 

voltage measurements under different ADC Test Conditions.
All values are updated continually (update rate is ~500ms). 

While running, the configuration can be changed on-the-fly. 

Simply changing a configuration item (discharge cells for ex-

ample) and clicking the WRITE CONFIG button will implement 

the new configuration and return to continuous operation.
A green box with the label ON in the lower right corner 

of the GUI indicates that the system is running continu-

ously. A red box with the label OFF means that the system 

is stopped and waiting for a new command to be sent.

DATALOGGING OPERATION

The GUI program can “datalog” or store cell voltage re-

sults in a CSV (Comma Separated Value *.csv) file. This 

feature is useful in characterizing cell voltages over time. 

Datalogging operates similarly to continuous operation but 

has the added functionality of storing results in a CSV file.
1. At the upper left of the GUI, click on the Datalog Menu 

then Enable Datalog. 

Summary of Contents for LTC6811-1

Page 1: ...ogy and the Linear logo and Linduino are registered trademarks and QuikEval is a trademark of Linear Technology Corporation All other trademarks are the property of their respective owners Photo 1 Connecting a Two Board Stack to a PC Design files for this circuit board are available at http www linear com demo DC2259A Alternatively for a simple demo connect twelve 100Ω resistorsbetweeneachcontactf...

Page 2: ...2 dc2259af DEMO MANUAL DC2259A Photo 2 Connections and Jumpers DESCRIPTION ...

Page 3: ...3 dc2259af DEMO MANUAL DC2259A Figure 1 Simple Cell Simulator Using Resistors DESCRIPTION ...

Page 4: ...sed n Reconfiguration of the first DC2259A to have ISOMD jumpers JP1 JP2 and JP3 changed to the 1 position like the other boards SOFTWARE SETUP To use the DC2026 USB interface board download the free program called QuikEval from http www linear com designtools software TheGUIprogramisprovidedinazippedfile LTC6804 6811_ GUI_Vxx zip 1 Unzip this folder 2 Run the setup exe file to start installation ...

Page 5: ...should be a match green PEC oval on stack display When any configuration information is changed on the screen the WRITE CONFIG command button will be il luminated serving as a reminder that this command still needs to be executed Set REFUP to 1 followed by a WRITE CONFIG command The Watchdog Timer WDT will now be prevented from expiring by issuing a repeating POLL ADC command and the stack is read...

Page 6: ...sholds appropriate for the cells being monitored The voltage value entered will be rounded to the actual value used by the LTC6811 and displayed in the box The voltage ranges for these thresholds is 0V to 6 5520V These monitor thresholds can be applied globally to each and every cell in the system or customized for the cells connected to an individual board by clicking the desired optionbutton Ind...

Page 7: ... case 7 Continuous Operation OPERATING THE CONTROL SCREEN For convenience the control panel allows for continuous operation of the DC2259A board When the command button labeled START CONTINUOUS READ CELLS is se lected the GUI operates in a continuous loop executing the following command sequence automatically n Start cell voltage n Read cell voltage groups A 1 3 B 4 6 C 7 9 and D 10 12 n Read flag...

Page 8: ...Monitor LTC6804 2 Click on the START CONTINUOUS READ CELLS com mand button to start datalogging onto a new CSV file ElapsedTime TotaltimeofDatalogfromstarttofinish Total Data Points Total data points of Datalog from start to finish Refresh Time in seconds S between each Read Cells command also known as Sample or Update Rate 3 ClickontheSTOPCONTINUOUSREADCELLScommand button to stop datalogging and ...

Page 9: ...M and set the Ref Up and voltages accordingly COLOR CODED STATUS PANEL The color coded status panel will expand to include all boards connected in a stack Each small square in this array represents an individual battery in the stack of boards The intent of this display is to provide a way to see the status of all cells at a glance The significance of the colors used is explained in the legend on t...

Page 10: ...TORY INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE EXCEPT TO THE EXTENT OF THIS INDEMNITY NEITHER PARTY SHALL BE LIABLE TO THE OTHER FOR ANY INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES The user assumes all responsibility and liability for proper and safe handling of the goods Further the user releases LTC from all claims arising from the handling or use o...

Page 11: ...Mouser Electronics Authorized Distributor Click to View Pricing Inventory Delivery Lifecycle Information Analog Devices Inc DC2259A ...

Reviews: