LTC1760
44
1760fc
For more information
www.linear.com/LTC1760
CSP
1760 F11
DIRECTION OF CHARGING CURRENT
R
SNS
CSN
Figure 12. Kelvin Sensing of Charging Current
2. The control IC needs to be close to the switching FET’s
gate terminals. Keep the gate drive signals short for a
clean FET drive. This includes IC supply pins that connect
to the switching FET source pins. The IC can be placed
on the opposite side of the PCB relative to above.
3. Place inductor input as close as possible to switching
FET’s output connection. Minimize the surface area of
this trace. Make the trace width the minimum amount
needed to support current—no copper fills or pours.
Avoid running the connection using multiple layers in
parallel. Minimize capacitance from this node to any
other trace or plane.
4. Place the output current sense resistor right next to
the inductor output but oriented such that the IC’s
current sense feedback traces going to resistor are not
long. The feedback traces need to be routed together
as a single pair on the same layer at any given time
with smallest trace spacing possible. Locate any filter
component on these traces next to the IC and not at
the sense resistor location.
5. Place output capacitors next to the sense resistor output
and ground.
6. Output capacitor ground connections need to feed into
same copper that connects to the input capacitor ground
before tying back into system ground.
General Rules
7. Connection of switching ground to system ground or
internal ground plane should be single point. If the
system has an internal system ground plane, a good
way to do this is to cluster vias into a single star point
to make the connection.
8. Route analog ground as a trace tied back to IC ground
(analog ground pin if present) before connecting to any
other ground. Avoid using the system ground plane.
CAD trick: make analog ground a separate ground net
and use a 0Ω resistor to tie analog ground to system
ground.
9. A good rule of thumb for via count for a given high
current path is to use 0.5A per via. Be consistent.
10. If possible, place all the parts listed above on the
same PCB layer.
11. Copper fills or pours are good for all power connections
except as noted above in Rule 3. You can also use cop-
per planes on multiple layers in parallel too—this helps
with thermal management and lower trace inductance
improving EMI performance further.
12. For best current programming accuracy provide a
Kelvin connection from R
SENSE
to CSP and BAT. See
Figure 12 as an example.
It is important to keep the parasitic capacitance on the R
T
,
CSP and BAT pins to a minimum. The traces connecting
these pins to their respective resistors should be as short
as possible.
Important Safety Notes
Although every effort is made to meet and exceed all
required “SMBus Charger V1.1” safety features it is the
responsibility of the battery pack to protect itself from
excessive currents or voltages. The LTC1760 is not itself
a safety device. Consult your battery pack manufacturer
for more information.