9.2  Connection and Pressurisation 

SODA PYGMY 25 GREEN LINE

                                                                                                                   

1.   Water inlet  

2.   Inlet of CO

2

3.   Pressure reducer CO

2

4.   Water Filter

5.   Main water connection (drinking water)

6.   Aqua Stop (recommended)

7.  Water hose 

8.  CO

2

 hose

9.  Python

10. Speed fitting 9,5 x 8 mm

11. Water outlet for production of cooled 

water

12. Water outlet for production of carbonated 

water

figure

  7 A

figure

  7 B

9.3  Connection and Pressurisation 

SODA AS-45 GREEN LINE

                                                                                                                               

1.   Water inlet for chilling 

2.   Water inlet for production ofcarbonated water 

3.   Inlet of CO

2

4.   Pressure reducer CO

2

5.   Y 8 x 8 x 8 mm speed fitting 

6.   Pressure reducer for water 

7.  Water Filter

8.  Main water connection (drinking 

water)

9.  Aqua Stop (recommended)

7.  Water hose

8.  CO

2

 hose

Variant

  

A:  

SODA WATER / COLD WATER

Set the pressure

   min. 2,5 Bar

   max. 3,0 Bar

Set the pressure

   min. 3,5 Bar

   max. 4,5 Bar

Set the pressure

   min. 3,5 Bar

   max. 4,5 Bar

Summary of Contents for EXTERNAL SODA WATER MAKER

Page 1: ...SODA WATER MAKERS LINDR Number 015 2020 REV00 Valid 2020 07 01 INSTRUCTION MANUAL ENGLISH ...

Page 2: ...tains important information necessary to ensure that all operations are done pro perly and safely WARNING Not following instructions may cause injury or damage the device SYMBOLS AND MARKINGS USED IN THE MANUAL DANGER Risk of injury by electrical current NOTE This symbol indicates information and re commendations for the user WARNING The cooling system contains flammable coolant R290 propane LINDR...

Page 3: ...tion 10 Temperature and adjustment 11 How to work with speed fittings 12 Water pressure reducer 13 Keg coupler assembly 14 Keg tapping and untapping 15 Putting into operation 16 Recommended accessories 17 Table of malfunctions 18 Spare parts 19 Cleaning the condenser 20 Inspection before every use 21 Periodic checks 22 Maintenance 23 Environmental protection 24 Technical data 4 4 4 4 5 6 6 6 6 10 ...

Page 4: ...ge caused by activities carried out on this device without observing the following instructions WARNING Children aged 15 or more and persons with reduced physical sensory or mental capabilities or insufficient experien ce and knowledge may only use the device when supervised or instructed in safe use of the appliance and familiarised with potential dangers WARNING Children must not be allowed to p...

Page 5: ...NG Do not use open flame or po tential sources of sparks in the vicinity of a cooler using R290 coolant WARNING After unpacking place the coo ler so that heat created by the cooling unit can be vented sufficiently WARNING Do not place objects that could prevent air circulation on top of the cooler 5 INSTALLATION AND PLACEMENT Place the device onto a stable level surface maximum permitted inclinati...

Page 6: ...ty are our property The legitimacy of the warranty claim is always decided by an authorised service centre Warranty provided by a retailer outsi de of the territory of the Czech Republic is go verned by the agreement between the retailer and the buyer in their mutual relationship this agreement is not directly linked to the ma nufacturer The agreement does not give the buyer the right to submit wa...

Page 7: ...production of carbonated water figure 7 A figure 7 B 9 3 Connection and Pressurisation SODA AS 45 GREEN LINE 1 Water inlet for chilling 2 Water inlet for production ofcarbonated water 3 Inlet of CO2 4 Pressure reducer CO2 5 Y 8 x 8 x 8 mm speed fitting 6 Pressure reducer for water 7 Water Filter 8 Main water connection drinking water 9 Aqua Stop recommended 7 Water hose 8 CO2 hose Variant A SODA W...

Page 8: ...ariant B SODA WATER BEVERAGE Set the pressure according to the type of beverage 1 7 3 0 Bar 9 5 Connection and Pressurisation EXTERNAL SODA WATER MAKER figure 8 B 1 Water inlet 2 Inlet of CO2 3 Pressure reducer CO2 4 Water Filter 5 Main water connection drinking water 6 Aqua Stop recommended 7 Pressure reducer for water 8 Outlet SODA 9 Water hose 10 CO2 hose 11 Switch On Off 12 Cooler Max inlet wa...

Page 9: ...r 2 st CO2 12 Y 8 x 8 x 8 mm speed fitting 13 Keg coupler A system S system M system 14 Beverage 15 Python 16 Speed fitting 9 5 x 8 mm 3x 17 Speed fitting 9 5 x 8 mm 2x 18 Water hose 19 CO2 hose figure 9 a Set the pressure min 2 5 Bar max 3 0 Bar Set the pressure min 3 5 Bar max 4 5 Bar WARNING Check the level and cleanliness of the water bath in the plastic container SODA AS 45 GREEN LINE a SODA ...

Page 10: ... 10 e WARNING If you do not hold the grey ring but pull at the hose the speed fitting will cut even deeper into the hose WARNING Hoses must not be pressurised during removal 11 HOW TO WORK WITH SPEED FITTINGS 11 1 Speed Fitting Installation Grasp the speed fitting and insert the hose all the way inside the speed fitting body ca 20 mm The end of the hose must be straight so that it plugs fully into...

Page 11: ...nometer figure 11 B figure 11 C figure 11 D ZPĚTNÝ VENTIL figure 11 E figure 11 F figure 11 A WARNING Before you screw the speed fitting onto the 5 8 thread make sure the keg coupler air inlet for delivery medium has a lip valve check valve fitted on it CHECK VALVE 13 KEG COUPLER ASSEMBLY 13 1 Outlet for Keg Pressurisation Variant of connection with the use of a bushing the hose is fitted onto the...

Page 12: ...TAPPING 14 1 Keg Tapping Procedure for tapping a keg using an S system keg coupler WARNING Make sure the adapter is clean before tapping the keg S system keg coupler 11 2 Outlet for Beverage Screw an F 5 8 x 3 8 9 5 mm speed fitting onto the keg coupler ...

Page 13: ...SODA WATER MAKERS 13 figure 13 A figure 13 b figure 13 c figure 13 d figure 13 e 14 2 Keg Untapping Procedure for untapping a keg using an S system keg coupler figure 13 f figure 13 g ...

Page 14: ... 14 A 14 3 Keg Tapping Procedure for tapping a keg using an A system keg coupler A system keg coupler figure 14b figure 14 c WARNING Make sure the adapter is clean before tapping the keg figure 14 d figure 14 e ...

Page 15: ...e a drink WARNING If you discover a leak turn off the device Fix any leaks found on the tubing If a leak is found inside the device or you are unsure how to proceed contact a service centre 16 RECOMMENDED ACCESSORIES AquaStop Water filter is required for the correct operation of the device Water pressure reducer is required for the correct operation of the device Tubes and fittings NOTE The recomm...

Page 16: ... min to 3 5 Bar max 4 5 Bar Check or replace the water filter The beverage is chilled only a little Wrong setting of the thermo stat Bad air circulation The machine overheats Turn the thermostat knob clockwise to No 7 Make sure the condenser plate are not clogged Place the machine to a cooler surroundings The fittings do not seal properly Poorly inserted tube Scratches on the hose Pull out the tub...

Page 17: ...y than 1x a month WARNING Do not use the device if defects or malfunctions are found 18 SPARE PARTS When ordering spare parts always provide the following product type production year product s serial number Ordering Components ALWAYS USE ORIGINAL COMPONENTS The manufacturer or supplier bear no responsibility for non original components or components not recommended by the manufacturer Do not forg...

Page 18: ...ck the cooling unit s con denser and clean it regularly 1x a year have an engineering inspector check the electrical safety of the device 23 ENVIRONMENTAL PROTECTION Waste Sorting This product must not be disposed of in communal waste Electrical waste in the Czech Republic is disposed of within the Rema System www remasystem cz In countries other than the Czech Republic waste sorting is subject to...

Page 19: ...WxDxH MM TYPE OF REFRIGERANT NET WEIGHT KG SODA PYGMY GREEN LINE 1 8 310 25 20 1 11 0 2 10 220 240V 50Hz 1 391 1 70 180x300x420 R290 19 0 SODA PYGMY 25 GREEN LINE 1 8 310 20 20 1 10 5 10 220 240V 50Hz 1 391 1 70 240x315x335 R290 17 0 SODA AS 45 GREEN LINE 1 8 310 45 25 1 7 0 2 10 220 240V 50Hz 1 299 1 50 440x270x430 R290 24 0 SODA AS 110 GREEN LINE 1 3 860 110 60 2 16 0 10 220 240V 50Hz 1 943 4 10...