17. TABLE OF MALFUNCTIONS:
Malfunction
Cause
Removal
The soda water does
not flow.
Pressure at the inlet has
exceeded 3.0 bar.
No water supply to the wa-
ter tap.
Inlet of pressure of CO
2
is
not open.
Water filter blocked.
Reduce the pressure on the water
valve min. to 2.5 Bar.-max 3.0 Bar.
Open the valve on the water tap.
Open and check the inlet pressure
CO
2
on the cylinder and adjust the
pressure of CO
2
min.to 3.5 Bar - max.
4.5 Bar.
Check or replace the water filter.
The beverage is chilled
only a little.
Wrong setting of the thermo
stat.
Bad air circulation.
The machine overheats.
Turn the thermostat knob clockwise
to No. 7.
Make sure the condenser plate are
not clogged
Place the machine to a cooler
surroundings.
The fittings do not seal
properly.
Poorly inserted tube.
Scratches on the hose.
Pull out the tube, check to see if the-
re are not any sharp edges, possibly
shorten with knife.
Pull out and shorten for about 2cm.
NOTE:
If the defect persists even after the above steps are taken, contact a service centre.