00$
/LIW7,*
0,*
0,*
3XOVH
6PRRWKDUF
0XOWLSURFHVV
BOC welding machines are designed and manufactured to conform
to IEC 60974 or AS 60974. This Standard not only covers the machine
but also the input cable and plug requirements including the size of
the plug that should be used.
X
Rated duty cycle
I
0
Rated no-load
supply current
I
1
Rated
supply current
AS 60974-1
Formula in clause 3.33
Maximum effective supply current
I
1eff
=
√
I
12
× X + I
02
(1-X)
The I1eff determines the correct plug, input cable
and input current required for each machine.
10A
I
1eff
≤
I
1eff
≤
I
1eff
≤
I
1eff
≤
1.5 – 2.5 mm
2
min – max
cable size
size must be indicated
on the cable
15A
1.5 – 4 mm
2
25A
2.5 – 6 mm
2
32A
4 – 10 mm
2
Before operating your welding machine, follow the instructions in the operating
manual. For more information refer to WTIA TN 22 – Welding Electrical Safety (Revised
2003) and WTIA TN 07 Health & Safety in Welding. If you have any queries please
contact BOC 131 262 (AU), 1800 111 333 (NZ).