7
Ékszíjas meghajtású, olajkenésű, dugatt
LINCOS Slovenia
STD-3550
Two Post Lift - Electrical Release
STEP TWO: MOUNTING TWO COLUMNS, POWER UNIT COLUMN FIRST THEN
THE OTHER.
1. Drill each anchor hole in the concrete using a rotary hammer drill. To assure
full holding power, do not ream the hole or allow drill to wobble.
2. After drilling, remove dust thoroughly from each hole and make certain that the
column remains aligned with the chalk line during this process
3. If shimming is required, insert the shims as necessary under the base plate so
that when the anchor bolts are tightened, the columns will be plumb.
4. With the shims and anchor bolts in place, tighten by securing the nut to the
base then turning. 2-3 full turns clockwise. DO NOT use an impact wrench for
this procedure.
5. Position the other column at the designated chalk locations and secure to the
floor following the same procedures as outlined in step 1,2,3,4.
STEP THREE: MOUNTING THE OVERHEAD BEAM (FOR CLEARFLOOR LIFT)
1.
Using a lifting device to raise the overhead beam into position on top of the
columns. Bolt the beam to columns with bolt and nut and washer supplied with
the product.
STEP FOUR: MOUNTING POWER UNIT, SAFETY DEVICE and CONTROL BOX.
1. Attach the power unit to the main column with supplied tools and parts.
Fill the reservoir with hydraulic oil.
2. Mount the safety plate and electromagnet on column. (parts in spare parts
box). Put the safety plate inside column, and then fix together with the
electromagnet on column back. Four safety plate and electromagnets are in
same
way
mounting.
(Refer to Fig A-1, A-2)
3. Wire connection for control box.
On power unit column, cut the wire (circular), connect two blue wires together,
and then two black wires together. Then connect with the electromagnet wire.
4PCS electromagnets in same connect way.
4. Mount control box, Wire connection.
Fix the control box on the column, cut the wire (circular) for electromagnet, to
connect the blue and black wire with QQ in the box. Then another blue and
black wire for magnet valve on power unit, then connect with YY in the