![Lincoln Quicklub SSV D Series Operating Instructions Manual Download Page 47](http://html1.mh-extra.com/html/lincoln/quicklub-ssv-d-series/quicklub-ssv-d-series_operating-instructions-manual_1917732047.webp)
Subject to modifications
User Manual
Operating Instructions
2.2A-20003-B07
LINCOLN GmbH • Postfach 1263 • D-69183 Walldorf • Tel +49 (6227) 33-0 • Fax +49 (6227) 33-259
Page 19 of 26
Operation, continuation
Adapting the Lubricant Output by Cross-porting of Outlets , continuation
Tube fittings, push-in type (main or secondary metering devices)
1203b05
Fig. 27
Install the push-in type outlet fittings and the closure plugs in accordance with the dosage
2 -
Delivery hole of the metering piston
and
control
piston
10 - Closure plug with hex. socket head
4 -
Closure plug (M11 x 1),
piston
(with
chamfer)
11 - Inlet fitting
(optional with protection cap)
1)
9 -
Junction channel
1)
when desired
12 - Valve body assembly
Main metering device
- with reinforced collet
Secondary metering device
- with knurled collet
6001a02
NOTE
In the case of construction machines or
agricultural machines use high-pressure
hoses for the lubricant feed lines. In this
case, secondary metering devices (see
Fig. 27) must also be equipped with check
valves with reinforced collet (standard
flange, see page 4).
Single lubricant output
The simple lubricant output is the lubricant quantity dispensed
by a pair of pistons (metering and control piston) per stroke
and per outlet bore to one lubrication point (see page 22,
Tab. 2).
Multiple lubricant outputs
Close one or more outlets to increase the output of the outlet
below. Depending on the dosage (page 8, paragraph „Meter-
ing Screws“) several outputs add up (see fig. 28).
Outlets, left-hand side
Outlets, right-hand side
Delivery
No.
Dosage
Delivery
No.
Dosage
1014b05
Fig. 28
Dosage of multiple outputs
A -
clamping ring (brass)
Delivery 8 = dosage 10 + dosage 8
Delivery 2 = dosage 4 + dosage 2
Delivery 1 = dosage 5 + dosage 3 + dosage 1