Operation, continuation
Lubricant Distribution within the Metering Device, continuation
6504y05
Fig. 19
Application in case of odd number of lubrication points (here: 5 instead of 6)
Cross-porting of outlets, internal
For the lubricant metering devices SSV D 6/5 to 22/21
with an internal cross-porting of outlets (bypass metering
device), outlets 1 and 2 are connected (see broken-lined
junction channel between outlet 2 and 1).
One outlet of one side of the metering device is closed in
order to be able to use the double lubricant quantity on
the other side.
Outlet V =
V1
Phase 5
+ V2
Phase 6
+ V1
Phase 11
+ V2
Phase 12
Thus the cross-porting of outlets results in further meter-
ing possibilities:
From assigning one metering device outlet per lubrication
point to cross-porting all outlets to one lubrication point,
almost all combinations are practicable.
Cross-porting of outlets, external
Opposite outlets of metering devices SSV and SSV D
may also be cross-ported externally and then be con-
nected to a lube point with a tee piece.
6054b03
Fig. 20
External cross-porting of lubricant quantities, screw type