English 26 English
P.81 Electrode
Polarity
Used in place of DIP switches for configuration of the work and electrode sense
leads
"Positive" (default) = Most GMAW welding procedures use Electrode
Positive welding.
"Negative" = Most GTAW and some inner shield procedures use Electrode
Negative welding.
P.99 Show
Test
Modes
Uses for calibration and tests.
"No" (factory default) = Turned off;
"Yes" = Allows to selection test modes.
Note:
After the device has been restarted the P.99 is "NO".
P.323 System
Update
This parameter is active only when the USB Memory Stick (with upgrade file) is
connected to USB socket.
Cancel – goes back to Configuration Parameters menu
Accept – starts updating process
Service Menu
It allows the access to special service
functions.
WARNING
Service Menu is available when USB storage device is
connected.
Figure 63.
Table 16.
Symbol
Description
Service weld logs
Weld History
SnapShot
Service weld logs
– allows recording welding
parameters which were using during the welding.
To access the menu:
Make sure that USB device is connected to welding
machine
Access to the Settings and Configuration Menu.
Use the Right Knob [36] to highlight the Service Menu
icon
Press the Right Knob [36] – the recording process will
started.
Figure 64.
Press the Right Knob [36] to continue.
Figure 65.
Press the Left Knob [35] or Button [37] to exit
Recording icon will appear on the
Status
bar
[38].
Note:
To stop the recording go to Service
Menu and press the
Service weld logs