H-8
Setup Menu Parameters
Parameter Symbol
Selection / * Default Value
Parameter Number
Description
See Figure B.7
0
Set Up menu Exit
•
N.A.
1
Reset All Parameters
•
%
*
•
A
3
Start Current Set Unit
•
%
•
A
*
8
Bi-Level Current 2
Set Unit
•
%
*
•
A
10
Pulse Background
Current Units
•
%
•
A
*
17
Finish Current Set
Unit
•
40 A *
307
DC TIG HF Strike
Current
•
60 A *
306
DC LIFT TIG Strike
Current
•
30 A *
307
AC TIG HF TIG Strike
Current
•
Enabled
*
•
Disabled
214
2-Step trigger re-start
•
Enabled
•
Disabled
*
215
4-Step trigger re-start
•
Square
*
•
Sine
•
Triangle
101
AC Waveform Shape
•
Enabled
•
Disabled
*
998
Bi-Level Trigger
•
Enabled
•
Disabled
*
999
Spot Timer Trigger
•
Off
*
•
Enabled to 12 V
•
Enabled to 20 V
•
Enabled to 30 V
201
VRD Limit
•
500
Not Used
•
0 ÷ 10 10 *
552
Speaker Volume
•
-20 ÷ 20 10 *
553
Display Contrast
•
English
*
•
French
•
Spanish
554
Display Language
•
Display
Off
•
Display in 7-segment LED
•
Display
*
751
Output Current
Displayed
•
Display Off *
•
Display in 7-segment LED
•
Display
752
Output Voltage
Displayed
•
Display Off *
•
Display in 7-segment LED
•
Display
753
Input Phase
Displayed
•
Display Off *
•
Display in 7-segment LED
•
Display
754
Input Voltage
Displayed
This function sets the initial start energy limit. Set this number to a higher setting than the factory default if
needed to improve starting of large diameter tungsten electrodes.
•
0.5 to 1.0 manual start energy setting.
•
1.2 to 5.0 = max. Incrementing limit (See Note).
104
AC TIG Start Power
(for AC TIG only)
Note:
The machine will try to start the arc at a start power of 1. If the arc does not establish it will incrementally
increase the start power and try to restrike upto the set limit.
Table B.4