![Lincoln IMPINGER 1000 series Service Manual Download Page 57](http://html1.mh-extra.com/html/lincoln/impinger-1000-series/impinger-1000-series_service-manual_1917748057.webp)
Impinger I -–1000 Series Service Manual - Domestic
57
BURNER ALARM LIGHT - REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove two (2) wires from light assembly, note wire number and location.
3.
Grasp body of light assembly and slide sideways to remove.
4.
Reassemble in reverse order and check.
PILOT LIGHT (220V) - REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove switch access cover.
3.
Remove two (2) wires from light assembly, note wire number and location.
4.
Grasp body of light assembly and slide sideways to remove.
5.
Reassemble in reverse order and check.
IGNITER SENSOR ASSEMBLY - REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove gas valve assembly (See Gas Valve)
3.
Remove screws from burner tube and pull burner assembly out.
4.
Remove wire connectors from igniter sensor assembly.
5.
Remove screws from mounting bracket and remove assembly.
6.
Reassemble in reverse order and check system operation.
NOTE: After installation, check all pipe fittings for leaks.
BURNER BLOWER MOTOR – REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove screws around blower tube.
3.
Disconnect motor wiring and remove.
4.
Reassemble in reverse order and check system operation.
TEMPERATURE CONTROL BOARD - REPLACEMENT- MODEL 1030
1.
Remove control panel top and front cover.
2.
Remove potentiometer leads (3), note color and location.
3.
Remove thermocouple leads (2), note color and location (white:pos/red:neg.).
4.
Remove power and solenoid leads (4), note wire number and location.
5.
Remove screw and board assembly and replace.
6.
Reassemble in reverse order and check system operation.
NOTE:
When replacing #369174 with (new) #369728, turn temperature control to its
maximum position and allow oven 30 minute preheat then calibrate board as follows:
Place temperature probe between top fingers #2 and #3 (making sure probe is
not touching any metal) and adjust potentiometer P6 to a Maximum temperature
of 575°F.
1
2
3
6
7
P 3
P 5
P 6
11
10
9
L 1 120 VAC
L 2
LOAD
RED
BLACK
WHITE
+
-
THERMOCOUPLE
TYPE J
POTENTIOMETER
2.5 K OHMS
transformer marked with
green gold or silver dot
Summary of Contents for IMPINGER 1000 series
Page 8: ...Impinger I 1000 Series Service Manual Domestic 8 SCHEMATIC 1000 1001 ...
Page 9: ...Impinger I 1000 Series Service Manual Domestic 9 SCHEMATIC 1004 1005 ...
Page 10: ...Impinger I 1000 Series Service Manual Domestic 10 SCHEMATIC 1022 1023 S N Q19077 BELOW ...
Page 11: ...Impinger I 1000 Series Service Manual Domestic 11 SCHEMATIC 1022 1023 S N Q19078 ABOVE ...
Page 12: ...Impinger I 1000 Series Service Manual Domestic 12 SCHEMATIC 1040 1041 S N Q14279 BELOW ...
Page 13: ...Impinger I 1000 Series Service Manual Domestic 13 SCHEMATIC 1040 1041 S N Q14280 ABOVE ...
Page 14: ...Impinger I 1000 Series Service Manual Domestic 14 SCHEMATIC 1200 1201 ...
Page 15: ...Impinger I 1000 Series Service Manual Domestic 15 SCHEMATIC 1202 1203 S N Q14790 BELOW ...
Page 16: ...Impinger I 1000 Series Service Manual Domestic 16 SCHEMATIC 1202 1203 S N Q14791 ABOVE ...
Page 17: ...Impinger I 1000 Series Service Manual Domestic 17 SCHEMATIC 1204 1205 ...
Page 18: ...Impinger I 1000 Series Service Manual Domestic 18 SCHEMATIC 1240 1241 S N Q14279 BELOW ...
Page 19: ...Impinger I 1000 Series Service Manual Domestic 19 SCHEMATIC 1240 1241 S N Q14280 ABOVE ...
Page 59: ...Impinger I 1000 Series Service Manual Domestic 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 61: ...Impinger I 1000 Series Service Manual Domestic 61 BLOW UP 1000 1200 GENERAL ...
Page 63: ...Impinger I 1000 Series Service Manual Domestic 63 BLOW UP ACCESS DOOR 1050 DOOR ...
Page 67: ...Impinger I 1000 Series Service Manual Domestic 67 BLOW UP 1000 1001 1004 1005 S N 4390 ABOVE ...
Page 69: ...Impinger I 1000 Series Service Manual Domestic 69 BLOW UP 1022 1023 ...
Page 71: ...Impinger I 1000 Series Service Manual Domestic 71 BLOW UP 1040 1041 ...
Page 73: ...Impinger I 1000 Series Service Manual Domestic 73 BLOW UP 1200 1201 1204 1205 ...
Page 75: ...Impinger I 1000 Series Service Manual Domestic 75 BLOW UP 1202 1203 ...
Page 77: ...Impinger I 1000 Series Service Manual Domestic 77 BLOW UP 1240 1241 ...
Page 79: ...Impinger I 1000 Series Service Manual Domestic 79 BLOW UP OVEN BACK GAS ...
Page 81: ...Impinger I 1000 Series Service Manual Domestic 81 BLOW UP OVEN BACK ELECTRIC ...
Page 85: ...Impinger I 1000 Series Service Manual Domestic 85 BLOW UP SERIES 1000 CONVEYOR ...
Page 87: ...Impinger I 1000 Series Service Manual Domestic 87 BLOW UP SERIES 1200 CONVEYOR CONTROL ...
Page 89: ...Impinger I 1000 Series Service Manual Domestic 89 BLOW UP SERIES 1200 CONVEYOR ...
Page 90: ...Impinger I 1000 Series Service Manual Domestic 90 This page intentionally left blank ...
Page 91: ...Impinger I 1000 Series Service Manual Domestic 91 This page intentionally left blank ...
Page 92: ...Impinger I 1000 Series Service Manual Domestic 92 ...