![Lincoln IMPINGER 1000 series Service Manual Download Page 28](http://html1.mh-extra.com/html/lincoln/impinger-1000-series/impinger-1000-series_service-manual_1917748028.webp)
Impinger I -–1000 Series Service Manual - Domestic
28
Conveyor Gear Motor
If DC voltage is present at A+ and A- and the motor
does not run, first check the mini breaker and then
the conveyor. Refer to the next possible cause.
Check the leads to the motor for evidence of any
shorts or opens, and each lead to ground. If the
motor fails the above tests, replace motor. Remove
dust cover from the top of the motor and rotate
motor shaft to determine if there is a locked rotor or
a locked gear box (use care so encoder disc is not
damaged).
Conveyor
Check for any mechanical misalignment or
improper adjustment. Also check for worn
bearings. The Installation and Operations Manual
shows proper conveyor belt adjustment. A
conveyor belt that is over tightened will cause
excessive bearing wear and sometimes, irregular
speed.
Power Supply
Check power supply at the DC control board for the
120 VAC at board terminals L1 and L2. If voltage is
not present, check main circuit breakers.
Tach generator and DC Motor
Control Board
With the power to the DC motor control board
turned off, remove the leads from terminals T1 and
T2.Place the test leads of a digital meter on the
tach leads, turn power on, and the meter reading
should be approximately 30 to 35 VDC. This
reading should be steady within ± 0.2 to 0.3 VDC.
If this reading is not 0.5 VDC, place the
test meter probes on terminals A+ and A-. The
meter reading should be approximately 150 to 160
VDC and steady within approximately 2 VDC. If the
tach. voltage is unsteady, and the board output is
steady, check the coupling for loose set screws or
any type of damage. If the coupling checks good,
the tach. is usually bad. If the board voltage output
is unsteady beyond limits, then the board is
probably bad. Always check the speed pot. Be sure
it is okay before changing a board or tach. This test
is not always 100% accurate as this test is not
performed at operating speeds. However, this test
is the best method currently available.
Readjustment should always be attempted at least
once before replacement. See procedure for board
adjustment on page 44.
Conveyor speed
varying or intermittent
DC Gearmotor
If the DC control board is steady then the problem
may be the motor or gearbox. Check the brushes
in the motor for excessive arching and/or unusual
wear. Check the motor and gearbox from
instruction located on page 27 under "possible
cause" listing "Conveyor gear motor".
Voltage Supply
Check incoming voltage supply at Line 1 to neutral.
There should be a voltage reading of 120 VAC.
Fan Switch
See procedure for checking on page 20.
Conveyor Switch
Check for 120 VAC to conveyor switch. If no
voltage is present, trace wiring back to the fan
switch. WITH POWER OFF: Check continuity
between switch terminals.
Conveyor Fuse (3A)
Check, replace if necessary.
Conveyor will not
run(S/N Q19078 &
Up1000 Series) (S/N
Q14791 & Up1200
Series)
Fuseholder
Check, replace if necessary.
Summary of Contents for IMPINGER 1000 series
Page 8: ...Impinger I 1000 Series Service Manual Domestic 8 SCHEMATIC 1000 1001 ...
Page 9: ...Impinger I 1000 Series Service Manual Domestic 9 SCHEMATIC 1004 1005 ...
Page 10: ...Impinger I 1000 Series Service Manual Domestic 10 SCHEMATIC 1022 1023 S N Q19077 BELOW ...
Page 11: ...Impinger I 1000 Series Service Manual Domestic 11 SCHEMATIC 1022 1023 S N Q19078 ABOVE ...
Page 12: ...Impinger I 1000 Series Service Manual Domestic 12 SCHEMATIC 1040 1041 S N Q14279 BELOW ...
Page 13: ...Impinger I 1000 Series Service Manual Domestic 13 SCHEMATIC 1040 1041 S N Q14280 ABOVE ...
Page 14: ...Impinger I 1000 Series Service Manual Domestic 14 SCHEMATIC 1200 1201 ...
Page 15: ...Impinger I 1000 Series Service Manual Domestic 15 SCHEMATIC 1202 1203 S N Q14790 BELOW ...
Page 16: ...Impinger I 1000 Series Service Manual Domestic 16 SCHEMATIC 1202 1203 S N Q14791 ABOVE ...
Page 17: ...Impinger I 1000 Series Service Manual Domestic 17 SCHEMATIC 1204 1205 ...
Page 18: ...Impinger I 1000 Series Service Manual Domestic 18 SCHEMATIC 1240 1241 S N Q14279 BELOW ...
Page 19: ...Impinger I 1000 Series Service Manual Domestic 19 SCHEMATIC 1240 1241 S N Q14280 ABOVE ...
Page 59: ...Impinger I 1000 Series Service Manual Domestic 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 61: ...Impinger I 1000 Series Service Manual Domestic 61 BLOW UP 1000 1200 GENERAL ...
Page 63: ...Impinger I 1000 Series Service Manual Domestic 63 BLOW UP ACCESS DOOR 1050 DOOR ...
Page 67: ...Impinger I 1000 Series Service Manual Domestic 67 BLOW UP 1000 1001 1004 1005 S N 4390 ABOVE ...
Page 69: ...Impinger I 1000 Series Service Manual Domestic 69 BLOW UP 1022 1023 ...
Page 71: ...Impinger I 1000 Series Service Manual Domestic 71 BLOW UP 1040 1041 ...
Page 73: ...Impinger I 1000 Series Service Manual Domestic 73 BLOW UP 1200 1201 1204 1205 ...
Page 75: ...Impinger I 1000 Series Service Manual Domestic 75 BLOW UP 1202 1203 ...
Page 77: ...Impinger I 1000 Series Service Manual Domestic 77 BLOW UP 1240 1241 ...
Page 79: ...Impinger I 1000 Series Service Manual Domestic 79 BLOW UP OVEN BACK GAS ...
Page 81: ...Impinger I 1000 Series Service Manual Domestic 81 BLOW UP OVEN BACK ELECTRIC ...
Page 85: ...Impinger I 1000 Series Service Manual Domestic 85 BLOW UP SERIES 1000 CONVEYOR ...
Page 87: ...Impinger I 1000 Series Service Manual Domestic 87 BLOW UP SERIES 1200 CONVEYOR CONTROL ...
Page 89: ...Impinger I 1000 Series Service Manual Domestic 89 BLOW UP SERIES 1200 CONVEYOR ...
Page 90: ...Impinger I 1000 Series Service Manual Domestic 90 This page intentionally left blank ...
Page 91: ...Impinger I 1000 Series Service Manual Domestic 91 This page intentionally left blank ...
Page 92: ...Impinger I 1000 Series Service Manual Domestic 92 ...