Impinger I -–1000 Series Service Manual - Domestic
38
TEMPERATURE CONTROL POTENTIOMETER – REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove one screw from control knob guard and move guard to one side.
3.
Remove knob and locknut on control pot. shaft and push out.
4.
Remove three (3) wires from temperature control board. Note wire numbers and location.
5.
Reassemble in reverse order.
MERCURY CONTACTOR
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Disconnect contactor wires and mark for reinstallation.
4.
Remove screws from mounting bracket and replace contactor.
NOTE:
Be sure contactor is not mounted upside down as this will cause a constant on condition.
5.
Reassemble in reverse order.
THERMOCOUPLE- REPLACEMENT
1.
Remove control panel top and front cover.
2.
Remove cover from relay box.
3.
Slide thermocouple out of oven chamber.
NOTE:
Remove conveyor and bottom fingers to aid in removal and installation of thermocouple.
4.
Remove two (2) wires from temperature control board. Make note of wire numbers or color and location
for reinstallation.
5.
Reassemble in reverse order making sure the metal end on the thermocouple is securely in the wire
form in the oven chamber.
THERMOCOUPLE MEASUREMENT CHART:
EXPLANATION: The junction temperature is the ambient air temperature where the thermocouple fastens
to the electronic temperature control board.
O
V
E
N
T
E
M
P
200°F 250°F 300°F 325°F 350°F 400°F 425°F 450°F 500°F 550°F 600°F
J
90°F
3.26
4.77
6.30
7.06
7.83
9.37 10.14 10.91 12.46 14.00 15.53
U
88°F
3.32
4.83
6.36
7.12
7.89
9.43 10.20 10.97 12.51 14.05 15.59
N
86°F
3.37
4.88
6.41
7.17
7.94
9.49 10.26 11.03 12.57 14.11 15.65
C
84°F
3.43
4.94
6.47
7.23
8.00
9.54 10.31 11.09 12.63 14.19 15.71
T
82°F
3.49
5.00
6.53
7.29
8.06
9.60 10.37 11.14 12.69 14.23 15.76
I
80°F
3.55
5.06
6.59
7.35
8.12
9.66 10.43 11.20 12.74 14.28 15.82
O
78°F
3.60
5.11
6.64
7.40
8.17
9.72 10.49 11.26 12.80 14.34 15.86
N
76°F
3.66
5.17
6.70
7.46
8.23
9.77 10.55 11.32 12.86 14.40 15.94
75°F
3.69
5.20
6.73
7.49
8.26
9.80 10.57 11.35 12.89 14.43 15.97
74°F
3.72
5.23
6.76
7.52
8.29
9.83 10.60 11.37 12.92 14.46 15.99
72°F
3.78
5.29
6.82
7.58
8.35
9.89 10.66 11.43 12.97 14.51 16.05
T
70°F
3.83
5.34
6.87
7.63
8.40
9.95 10.72 11.49 13.03 14.57 16.11
E
68°F
3.89
5.40
6.93
7.69
8.46 10.00 10.78 11.55 13.09 14.63 16.17
M
66°F
3.95
5.46
6.99
7.75
8.52 10.06 10.83 11.61 13.15 14.69 16.23
P
64°F
4.01
5.52
7.05
7.81
8.58 10.12 10.89 11.66 13.20 14.74 16.28
62°F
4.06
5.57
7.10
7.86
8.63 10.18 10.95 11.72 13.26 14.80 16.34
60°F
4.12
5.63
7.16
7.92
8.69 10.24 11.01 11.78 13.32 14.86 16.40
Summary of Contents for IMPINGER 1000 series
Page 8: ...Impinger I 1000 Series Service Manual Domestic 8 SCHEMATIC 1000 1001 ...
Page 9: ...Impinger I 1000 Series Service Manual Domestic 9 SCHEMATIC 1004 1005 ...
Page 10: ...Impinger I 1000 Series Service Manual Domestic 10 SCHEMATIC 1022 1023 S N Q19077 BELOW ...
Page 11: ...Impinger I 1000 Series Service Manual Domestic 11 SCHEMATIC 1022 1023 S N Q19078 ABOVE ...
Page 12: ...Impinger I 1000 Series Service Manual Domestic 12 SCHEMATIC 1040 1041 S N Q14279 BELOW ...
Page 13: ...Impinger I 1000 Series Service Manual Domestic 13 SCHEMATIC 1040 1041 S N Q14280 ABOVE ...
Page 14: ...Impinger I 1000 Series Service Manual Domestic 14 SCHEMATIC 1200 1201 ...
Page 15: ...Impinger I 1000 Series Service Manual Domestic 15 SCHEMATIC 1202 1203 S N Q14790 BELOW ...
Page 16: ...Impinger I 1000 Series Service Manual Domestic 16 SCHEMATIC 1202 1203 S N Q14791 ABOVE ...
Page 17: ...Impinger I 1000 Series Service Manual Domestic 17 SCHEMATIC 1204 1205 ...
Page 18: ...Impinger I 1000 Series Service Manual Domestic 18 SCHEMATIC 1240 1241 S N Q14279 BELOW ...
Page 19: ...Impinger I 1000 Series Service Manual Domestic 19 SCHEMATIC 1240 1241 S N Q14280 ABOVE ...
Page 59: ...Impinger I 1000 Series Service Manual Domestic 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 61: ...Impinger I 1000 Series Service Manual Domestic 61 BLOW UP 1000 1200 GENERAL ...
Page 63: ...Impinger I 1000 Series Service Manual Domestic 63 BLOW UP ACCESS DOOR 1050 DOOR ...
Page 67: ...Impinger I 1000 Series Service Manual Domestic 67 BLOW UP 1000 1001 1004 1005 S N 4390 ABOVE ...
Page 69: ...Impinger I 1000 Series Service Manual Domestic 69 BLOW UP 1022 1023 ...
Page 71: ...Impinger I 1000 Series Service Manual Domestic 71 BLOW UP 1040 1041 ...
Page 73: ...Impinger I 1000 Series Service Manual Domestic 73 BLOW UP 1200 1201 1204 1205 ...
Page 75: ...Impinger I 1000 Series Service Manual Domestic 75 BLOW UP 1202 1203 ...
Page 77: ...Impinger I 1000 Series Service Manual Domestic 77 BLOW UP 1240 1241 ...
Page 79: ...Impinger I 1000 Series Service Manual Domestic 79 BLOW UP OVEN BACK GAS ...
Page 81: ...Impinger I 1000 Series Service Manual Domestic 81 BLOW UP OVEN BACK ELECTRIC ...
Page 85: ...Impinger I 1000 Series Service Manual Domestic 85 BLOW UP SERIES 1000 CONVEYOR ...
Page 87: ...Impinger I 1000 Series Service Manual Domestic 87 BLOW UP SERIES 1200 CONVEYOR CONTROL ...
Page 89: ...Impinger I 1000 Series Service Manual Domestic 89 BLOW UP SERIES 1200 CONVEYOR ...
Page 90: ...Impinger I 1000 Series Service Manual Domestic 90 This page intentionally left blank ...
Page 91: ...Impinger I 1000 Series Service Manual Domestic 91 This page intentionally left blank ...
Page 92: ...Impinger I 1000 Series Service Manual Domestic 92 ...