![Lincoln IMPINGER 1000 series Service Manual Download Page 41](http://html1.mh-extra.com/html/lincoln/impinger-1000-series/impinger-1000-series_service-manual_1917748041.webp)
Impinger I -–1000 Series Service Manual - Domestic
41
FLAME SENSOR
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove burner assembly (see burner assembly).
4.
Disconnect one (1) wire from flame sensor.
5.
Remove flame sensor by removing one (1) mounting nut.
6.
Reassemble in reverse order.
NOTE:
Be sure flame sensor is not bent or touching any other burner parts.
BURNER IGNITOR
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove burner assembly.
4.
Remove flame sensor.
5.
Remove pilot shield and pilot shield extension.
6.
Remove burner igniter.
7.
Reassemble in reverse order.
NOTE: Be sure to reconnect burner igniter cable to ignition control.
TRANSFORMER 120/24 VAC
1.
Remove control panel top and front cover.
2.
Remove control box cover from burner blower motor.
NOTE: The complete burner blower motor assembly, with control box (PN 369359), is no longer
available. The blower motor assembly (PN 369265) has been changed to a
burner motor kit (PN 369366). If the burner blower motor or 24V transformer
(PN 369531 ) are replaced, the following modifications must be made:
3.
Shut off power at main breaker.
4.
Remove control box and components from burner blower motor.
5.
Mount transformer on air switch bracket (use transformer as template).
6.
Discard control box and relay. Material needed: #29 drill bit and #8 x 3/8" self tapping screws (3 each)
7.
See Burner blower motor section for wiring information.
8.
Replace covers and check system operation.
BURNER LIGHT (24 VAC) - GAS OVENS
1.
Shut off power at main breaker.
2.
Remove control panel top and front panel.
3.
Remove access cover.
4.
Remove two wires from burner light, note number and location.
5.
Grasp body of light assembly and slide sideways to remove.
6.
Reassemble in reverse order and check.
HEAT LIGHT (125 VAC) - ELECTRIC OVENS
1.
Shut off power at main breaker.
2.
Remove control panel top and front panel.
3.
Remove two (2) wires from heat light, note number and location.
4.
Grasp body of light assembly and slide sideways to remove.
5.
Reassemble in reverse order and check.
THERMOSTAT, Hl-LIMIT - ELECTRIC OVENS
1.
Shut off power at main breaker.
2.
Remove control panel top and front cover.
3.
Remove the two-(2) wires from the thermostat located on the back wall of the control box.
4.
Remove two (2)-mounting screws.
5.
Reassemble in reverse order.
NOTE:
Be sure to press red "reset" button on new thermostat to ensure that it is in the
"closed" position.
Summary of Contents for IMPINGER 1000 series
Page 8: ...Impinger I 1000 Series Service Manual Domestic 8 SCHEMATIC 1000 1001 ...
Page 9: ...Impinger I 1000 Series Service Manual Domestic 9 SCHEMATIC 1004 1005 ...
Page 10: ...Impinger I 1000 Series Service Manual Domestic 10 SCHEMATIC 1022 1023 S N Q19077 BELOW ...
Page 11: ...Impinger I 1000 Series Service Manual Domestic 11 SCHEMATIC 1022 1023 S N Q19078 ABOVE ...
Page 12: ...Impinger I 1000 Series Service Manual Domestic 12 SCHEMATIC 1040 1041 S N Q14279 BELOW ...
Page 13: ...Impinger I 1000 Series Service Manual Domestic 13 SCHEMATIC 1040 1041 S N Q14280 ABOVE ...
Page 14: ...Impinger I 1000 Series Service Manual Domestic 14 SCHEMATIC 1200 1201 ...
Page 15: ...Impinger I 1000 Series Service Manual Domestic 15 SCHEMATIC 1202 1203 S N Q14790 BELOW ...
Page 16: ...Impinger I 1000 Series Service Manual Domestic 16 SCHEMATIC 1202 1203 S N Q14791 ABOVE ...
Page 17: ...Impinger I 1000 Series Service Manual Domestic 17 SCHEMATIC 1204 1205 ...
Page 18: ...Impinger I 1000 Series Service Manual Domestic 18 SCHEMATIC 1240 1241 S N Q14279 BELOW ...
Page 19: ...Impinger I 1000 Series Service Manual Domestic 19 SCHEMATIC 1240 1241 S N Q14280 ABOVE ...
Page 59: ...Impinger I 1000 Series Service Manual Domestic 59 THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 61: ...Impinger I 1000 Series Service Manual Domestic 61 BLOW UP 1000 1200 GENERAL ...
Page 63: ...Impinger I 1000 Series Service Manual Domestic 63 BLOW UP ACCESS DOOR 1050 DOOR ...
Page 67: ...Impinger I 1000 Series Service Manual Domestic 67 BLOW UP 1000 1001 1004 1005 S N 4390 ABOVE ...
Page 69: ...Impinger I 1000 Series Service Manual Domestic 69 BLOW UP 1022 1023 ...
Page 71: ...Impinger I 1000 Series Service Manual Domestic 71 BLOW UP 1040 1041 ...
Page 73: ...Impinger I 1000 Series Service Manual Domestic 73 BLOW UP 1200 1201 1204 1205 ...
Page 75: ...Impinger I 1000 Series Service Manual Domestic 75 BLOW UP 1202 1203 ...
Page 77: ...Impinger I 1000 Series Service Manual Domestic 77 BLOW UP 1240 1241 ...
Page 79: ...Impinger I 1000 Series Service Manual Domestic 79 BLOW UP OVEN BACK GAS ...
Page 81: ...Impinger I 1000 Series Service Manual Domestic 81 BLOW UP OVEN BACK ELECTRIC ...
Page 85: ...Impinger I 1000 Series Service Manual Domestic 85 BLOW UP SERIES 1000 CONVEYOR ...
Page 87: ...Impinger I 1000 Series Service Manual Domestic 87 BLOW UP SERIES 1200 CONVEYOR CONTROL ...
Page 89: ...Impinger I 1000 Series Service Manual Domestic 89 BLOW UP SERIES 1200 CONVEYOR ...
Page 90: ...Impinger I 1000 Series Service Manual Domestic 90 This page intentionally left blank ...
Page 91: ...Impinger I 1000 Series Service Manual Domestic 91 This page intentionally left blank ...
Page 92: ...Impinger I 1000 Series Service Manual Domestic 92 ...