7. Click on the button to display the
WorkPoint Editor window. Check only those
wire feed speed points that have been
developed (only 150 in/min. at this point). The
WorkPoint Editor can also be used to change
the wire feed speed value of a workpoint.
Workpoints can have the same value but must
be in numerical order.
Select the
button to set the wave
shape parameters for all workpoints equal to
the wave shape parameters of the 150 in/min.
workpoint. Close the WorkPoint Editor window.
Appendix A
A-19
PULSE WAVE SHAPING PRINCIPLES
WAVE DESIGNER
WorkPoint Editor
WorkPoint Editor
1
0
2
3
4
5
6
7
8
9
10
11
50
700
80
850
110
1000
150
1200
205
300
400
600
inch / min
meter / min
Go Figure
28750032
6. The “Start”, “Short”, and “End” windows can
be adjusted at this time to optimize the
starting, shorting, and ending routines.
Start Control - Pulse
Start Control
For Wire Feed Speed
Stage 1 : Wire Run In
Stage 2 : Striking Pulse
Stage 3 : Arc Length Control
Stage 4 : Current Control
Start Volt
Start Time
Start Amps
Strike Peak Time
Strike Peak Amps
Open Circuit Volt
48.0
2.0
21.0
88
172
550
150
27850044
Our Experiment: We needed to adjust the
starting variables. With the feeder’s run-in
WFS set at 65 in/min, we set the starting
variables to control the starting routine. With
the assistance of ArcScope, we found good
settings with these values: start volt 21.0,
start time 35 milliseconds, and start current
180 amps. The OCV strike peak time and
amps were acceptable as set.
Summary of Contents for WAVE DESIGNER
Page 2: ......
Page 6: ...iv iv LICENSE INFORMATION WAVE DESIGNER...
Page 26: ...3 14 Section 3 SOFTWARE OPERATION WAVE DESIGNER...
Page 30: ...4 4 Section 4 ARCSCOPE WAVE DESIGNER...
Page 32: ...5 2 Section 5 TROUBLESHOOTING WAVE DESIGNER...
Page 54: ...A 22 Appendix A PULSE WAVE SHAPING PRINCIPLES WAVE DESIGNER...
Page 74: ...INDEX Index 4 WAVEDESIGNER...