English 10
English
11. Fuse F2: Use the 2A/400V (6,3x32mm) slow-blow
fuse. See "Spare Parts" chapter.
12. Fuse F1: Use the 2A/400V (6,3x32mm) slow-blow
fuse. See "Spare Parts" chapter.
13.
Cooler Power Supply Socket: Socket
supplies 400VAC for power circuit cooler.
The circuit is protected by a slow-blow
fuse [12].
WARNING
Read and understand the cooler manual before
connecting it to the machine.
14. Gas Heater Socket: U
sup
= 24VAC, P
max
= 80W.
User Interface
User Interface can be installed, in place of the replaceable
panel [4], which allows to adjust the welding parameters
from the power source. Panel with User Interface Kit can
be purchased separately (see "Accessories" chapter).
Description of the User Interface is available in the
operator’s manual od wire feeder IM3028, IM3034,
IM3045, IM3046, IM3052, IM3053 and the Guide supplied
with a Replaceable Front Panel.
Welding Cables Connection
Insert the plug of the work lead into the socket [5]. The
other end of this lead connects to the work piece with the
work clamp.
Connect the wire feeder to the power source:
Insert the positive welding cable into the output socket [6].
Insert the wire feeder control cable into the socket [7] (see
"Accessories" chapter, Source/wire feeder cable K10349-
PG-xM or K10349-PGW-xM).
Use the shortest possible cable lengths.
Water Cooler Connection
SPEEDTEC 405S, 405SP, 505S
and
505SP
work with
the water cooler
COOLARC 46
(see "Accessories"
chapter).
WARNING
Read and understand the cooler manual
before connecting it to the power source.
Before connecting cooler, refer to the
manual of wire feeder.
The
COOLARC 46
is supplied by welding power source
using 9-PIN socket.
Input voltages is 400V, 50/60Hz. Make sure that the
supply voltage of the unit matches the cooler’s rated
voltage.
13
Figure 3.
To connect the water cooler
COOLARC
46
to the power
source:
Turn off the power source and disconnect input plug.
Remove the cap from the Water Cooler Supply
Socket.
Insert 9-pin plug of the water cooler power lead into
the Water Cooler Power Supply Socket [13].
WARNING
Do not switch on the welding power source with the cooler
applied if the reservoir was not filled and the torch’s/gun’s
hoses are disconnected from the cooling unit. The no
observance of this warning may be cause internal
damages at the cooler unit.