B-2
OPERATION
B-2
5. THERMAL
• This status light indicates when the power source has
been driven into thermal overload. If the output terminals
were "ON", the "ON" light will blink indicating that the out-
put will be turned back on once the unit cools down to an
acceptable temperature level. If the unit was operating in
the "REMOTE" mode, the trigger will need to be opened
before or after the thermal has cleared and closed after
the machine has cooled down to an acceptable tempera-
ture to establish output.
6. CONTROL-REMOTE / LOCAL
• Two status lights indicate the location of output control as
pre-determined by the power sources auto-configure sys-
tem.
• The LOCAL display will be lit when control is at the power
source.
• The REMOTE display will be lit when a remote pot/control
is detected.
These Output Control configurations can be overridden
(switched) with the CONTROL push button. When
changed, the unit will power up in the configuration it was in
when it was last powered down.
Hidden Middle Control Panel – Process Set Up
Panel
7. WELD MODE SELECT -
The Mode Control button selects from the following
welding modes.
CC-STICK SOFT
: The Stick Soft process features
continuous control ranging from 5 to 425 amps. This
mode was intended for most SMAW applications, and
Arc Gouging.
• Arc Gouging: Setting the output of the Stick Soft
mode to 425 amps will enable the arc-gouging
mode. The actual output current will depend on the
size of carbon used. The recommended maximum
size carbon is 5/16".
• The Hot Start control regulates the starting current
at arc initiation. Hot Start can be adjusted from min-
imum (0), with no additional current added at arc
start, to maximum (10), with double the preset cur-
rent or 425 amps (max of machine) added for the
first second after arc initiation.
• The Arc Control regulates the Arc Force to adjust
the short circuit current. The minimum setting (-10)
will produce a "soft" arc and will produce minimal
spatter. The maximum setting (+10) will produce a
"crisp" arc and will minimize electrode sticking.
CC-STICK CRISP:
The Stick Crisp mode features
continuous control from 5 to 425 amps. This mode
was intended primarily for pipe welding applications.
• The Hot Start control regulates the starting current
at arc initiation. Hot Start can adjust starting current
up or down by 25% of the preset value. The recom-
mended setting for Hot Start is 5 where the initial
current is equal to the preset current.
• The Arc Control regulates the Arc Force to adjust
the short circuit current. The minimum setting (-10)
will produce a "soft" arc and will produce minimal
spatter. The maximum setting (+10) will produce a
"crisp" arc and will minimize electrode sticking.
EX350i
REMO
REMOTE
ON
ON
REMO
REMOTE
LOCAL
LOCAL
WELD TERMINALS
OUTPUT
CONTROL
SELECT
SELECT
MPS
A
OLTS
V
SELECT
SELECT
CC-STICK SOFT 7018
CC-STICK SOFT 7018
CC-STICK CRISP 6010
CC-STICK CRISP 6010
TIG GT
TIG GTAW
CV
CV-WIRE
-WIRE
CV
CV-FLUX CORED
-FLUX CORED
HO
HOT ST
T START
ARC CONTR
ARC CONTROL
OL
-4
+4
+2
-2
0
-6
+6
-10
SOFT
CRISP
+10
-8
+8
5
4
3
2
1
0
6
10
9
8
7
1
6
5
2
3
4
8
7
11
10
12
9
FIGURE 1
Summary of Contents for Red-D-Arc EX350i
Page 36: ...NOTES EX350I ...