PROBLEMS
(SYMPTOMS)
POSSIBLE AREAS OF
MISADJUSTMENTS(S)
RECOMMENDED
COURSE OF ACTION
F
-2
TROUBLESHOOTING
POWER MIG
®
360MP
OUTPUT PROBLEMS
Major physical or electrical damage
is evident.
Do not plug in machine or turn it on. Contact your
local Lincoln Authorized Field Service Facility.
If all recommended possible areas of
misadjustment have been checked and the
problem persists, Contact your local Lincoln
Authorized Field Service Facility.
No wire feed, Weld output or gas flow
when gun trigger is pulled. Fans does
NOT operate.
1. Make sure correct voltage is applied to the
machine.
2. Make certain that the power switch is in ON
position.
3. Make sure circuit breaker is reset.
No wire feed, Weld output or gas flow
when gun trigger is pulled. Fans
operate normally.
1. The thermostat may be tripped due to
overheating. Let machine cool. Weld at lower
duty cycle.
2. Check for obstructions in air flow. Check gun
trigger connections. See installation section.
3. Gun trigger may be faulty.
Arc is unstable – Poor starting.
1. Check for correct input voltage to machine.
2. Check machine reconnect panel is configured
properly for the applied voltage.
3. Check gun tip for wear or damage and proper
size – Replace.
4. Check for proper gas and flow rate for process.
5. Check work cable or loose or faulty
connections.
6. Check gun for damage or breaks.
7. Check for proper drive roll orientation and
alignment.
8. Check liner for proper size.
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR