Lincoln Electric OUTBACK 200 CE Operator'S Manual Download Page 9

 

 

When receiving the goods make sure that the product has 
not suffered damage during the transport, that there has 
not been rough handling or taking away of parts contained 
inside the packing or in the set. 
In case you find damages, rough handling or absence of 
parts (envelopes, manuals, etc.), we advise you to inform 
immediately our Technical Service. 
For eliminating the packing materials, the User must keep 
to the norms in force in his country. 
 
 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1)Take the machine (C) out of the shipment packing. 
Take out of the envelope (A) the user’s manual (B). 
2)Fit the handle as shown in the instructions (fitting: 
screws 
and spanner are supplied). 
3 ) Read: the user’s manual (B), the plates fixed on the 
machine, the data plate. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
In case you should transport or move the machine, keep 
to the instructions as per the figures. 
Be sure that the lifting devices are: correctly mounted, 
adequate for the weight of the machine with it’s 
packaging, and conform to local rules and regulations. 
Only authorized persons involved in the transport of the 
machine should be in the area of movement. 

 

 
Transportation must always take place with the engine off, 
electrical cables and starting battery disconnected and 
fuel tank empty. Be sure that the lifting devices are: 
correctly mounted, adequate for the weight of the 
machine with it’s packaging, and conform to local rules 
and regulations. 

 

Only authorized persons involved in the transport of the 
machine should be in the area of movement. 
 
This equipment is built in compliance with standard IEC-
EN60974-10. 
The equipment should be installed and used in 
accordance with the information below to achieve 
electromagnetic compatibility. The limits required by IEC-
EN60974-10 may not be adequate to completely eliminate 
interference when the affected equipment is in close 
proximity or has a high degree of sensitivity. In such cases 
it may be necessary to use other measures to further 
reduce interference 
 

This Class A equipment is not intended for use in 
residential locations where the electrical power is 
provided by the public low-voltage supply system. 
There may be potential difficulties in ensuring 
electromagnetic compatibility in those locations,  
due to conducted as well as radiated disturbances. 

 
The user is responsible for installing and using the arc 
welding equipment according to the manufacturer’s 
instructions. 
If electromagnetic disturbances are detected, then it shall 
be the responsibility of the user resolve the situation with 
the technical assistance of the manufacturer. 
In some cases this remedial action may be as simple as 
earthing the welding circuit (see note). In other cases, it 
could involve constructing an electromagnetic screen 
enclosing the welding power source and the work 
complete with 
associated filters 
In all cases electromagnetic disturbances shall be reduced 
to the point where they are no longer troublesome. 
 

NOTE

: The welding circuit may or may not be 

earthed for safety reasons. Changing the earthing 
arrangements should only be authorized by a person 
who is competent to assess whether the changes will 

 

 

 
 

 

 

 

 

 

Summary of Contents for OUTBACK 200 CE

Page 1: ...IM3135 08 2020 REV00 OUTBACK 200 CE OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland www lincolnelectric eu...

Page 2: ...ssure 2010 ISO 8528 10 1998 Reciprocating internal combustion engine driven alternating current generating sets Part 10 Measurement of airborne noise by the enveloping surface method EN60204 1 2006 Sa...

Page 3: ...dealer For ease of use please enter your product identification data in the table below Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where...

Page 4: ...Flow Filter Stage V Carburator Mechanical Electronic AIR CLEANER ENGINE IDLER MUFFLER ENGINE PROTECTION Single Element Not present Low noise Muffler with spark arrestor Shutdown on low oil level ENGI...

Page 5: ...reasons Follow your local and national standards for installation and use Changing the earthing arrangements should only be authorized by a person who is competent to access whether the changes will i...

Page 6: ...iece Where the workpiece is not bonded to earth for electrical safety not connected to earth because of its size and position e g ships hull or building steelwork a connection bonding the workpiece to...

Page 7: ...FIELDS MAY BE DANGEROUS Electric current flowing through any conductor creates electric and magnetic fields EMF EMF fields may interfere with some pacemakers and welders having a pacemaker shall cons...

Page 8: ...uit single phase power for the AC auxiliary outlets The OUTBACK 200 CE engine driven welder is a unit which ensures the dual function as a current source for are welding current generator for generati...

Page 9: ...ea of movement This equipment is built in compliance with standard IEC EN60974 10 The equipment should be installed and used in accordance with the information below to achieve electromagnetic compati...

Page 10: ...starting engine Keep sparks and flame away from tank Oil The OUTBACK 200 CE is shipped with the engine crankcase filled Check the oil level before starting the engine If it is not up to the full mark...

Page 11: ...and sizes of cables Cable Length Cable Size for 170 A 60 Duty Cycle 0 30 meters 25mmq 30 46 meters 25mmq 46 61 meters 35mmq Cable Installation Install the welding cables to your OUTBACK 200 CE as foll...

Page 12: ...supplying only one tool at a time the protection against indirect contact is assured by electrical separation Therefore the machine MUST NOT be intentionally connected to earth attaching cables must b...

Page 13: ...r emits chemicals known to the state of California to cause cancer birth defects or other reproductive harm SAFETY LABEL LOCATION This label warns you of potential hazards that can cause serious injur...

Page 14: ...il or gasoline leaks Remove any excessive dirt or debris especially around the muffler and recoil starter Look for signs of damage Check that all shields and covers are in place and all nuts bolts and...

Page 15: ...provided by the equipment manufacturer 3 Move the throttle lever away from the MIN position about 1 3 of the way toward the MAX position Some engine applications use a remote mounted throttle control...

Page 16: ...mounted throttle control rather than the engine mounted throttle lever shown here 2 Turn the engine switch to the OFF position 3 Turn the fuel valve lever to the OFF position SETTING ENGINE SPEED Pos...

Page 17: ...ential hazards Carbon monoxide poisoning from engine exhaust Operate outside away from open windows or doors Burns from hot parts Let the engine and exhaust system cool before touching Injury from mov...

Page 18: ...bottom of the maximum fuel level limit of the fuel tank Do not overfill Wipe up spilled fuel before starting the engine 3 Refuel carefully to avoid spilling fuel Do not fill the fuel tank completely...

Page 19: ...onvenience of an unexpected shutdown fill to the upper limit and check the oil level regularly 4 Install the oil filler cap dipstick and tighten securely REDUCTION CASE OIL applicable types Reccomende...

Page 20: ...hey are damaged Always replace the paper air filter element at the scheduled interval CYCLONE DUAL FILTER ELEMENT 5 Clean the air filter elements if they are to be reused Paperairfilterelement Tapthef...

Page 21: ...on flammable solvent and dry thecase 5 Fill the air cleaner case to the OIL LEVEL mark with the same oil that is recommended for the engine Oil capacities GX390 80 cm3 6 Reassemble the air cleaner and...

Page 22: ...ling washer When installing a new spark plug tighten 1 2 turn after the spark plug seats to compress the washer When reinstalling the original spark plug tighten 1 8 1 4 turn after the spark plug seat...

Page 23: ...ng greater than the one originally equipped with the engine Serious damage to the electrical system or a fire could result 3 Reinstall the rear cover Install the 6 12 mm screw and tighten it securely...

Page 24: ...e We expressly disclaim any warranty of any kind including any warranty of fitness for any customer s particular purpose with respect to such information or advice As a matter of practical considerati...

Page 25: ...quipment that has reached the end of its life must be collected separately and returned to an environmentally compatible recycling facility As the owner of the equipment you should get information on...

Page 26: ...23 Electrical Schematic...

Page 27: ...24...

Page 28: ...25...

Page 29: ...26...

Page 30: ...ccessories K14295 1 KIT HANDLES OUTBACK 200 K14296 1 KIT WHEELS OUTBACK 200 W000260684 KIT 25C50 kit with ground cable and cable electrode hoder W000011139 KIT 35C50 kit with ground cable and cable el...

Reviews: