F-67
TROUBLESHOOTING & REPAIR
F-67
8. Test Voltmeter PC Board Accuracy
• Use a test meter with at least 3-
1/2 digits and +/- 0.5% accuracy.
• Connect the + probe to lead #517
and the - probe to lead #510C.
Do not disconnect plug.
Note: The coating will have to be
removed from the test points to ensure
accurate meter readings.
• With the NA-5 voltmeter reading
SET values of STRIKE voltage,
adjust the strike voltage control
until the NA-5 voltmeter matches
the settings in the table below.
• If the test meter does not match
the readings, the voltmeter PC
board may be faulty.
METER CIRCUIT ACCURACY TEST
(Continued)
NA-5
NA-5 SET VOLTS READING
TEST VOLTMETER READING
15.0VDC
1.50VDC +/- .04
30.0VDC
3.00VDC +/- .04
60.0VDC
6.00VDC +/- .06
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC